Electromagnetic flowmeter Promag 5W5B

Brand: Endress+Hauser

Electromagnetic flowmeter Promag 5W5B

Brand: Endress+Hauser

Forberg Smith, Endress+Hauser's exclusive USA representative in:
KY MI OH PA  Parts of WI WV 

Extended Extended
Heartbeat Technology Heartbeat Technology

Specs at a Glance

Measuring range:
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Medium temperature range:
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Max. process pressure:
PN 40, Class 300, 20K
Max. measurement error:
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Wetted materials:
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

Field of application

Electromagnetic flowmeter
Inline version.
Application: Dedicated to the
measurement of industrial or municipal
water and wastewater.
International drinking water approvals.
Installation length: DVGW/ISO conform.
Remote version.
4-line display, touch control.

Specifications

Industry

  • Water, Wastewater & Waste
  • Power & Energy
  • Mining, Minerals & Metals

Product Family

  • Promag

Liquids

Product headline

  • Specialist for demanding water and wastewater applications as remote version with up to 4 I/Os.
  • Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
  • Dedicated to the measurement of industrial or municipal water and wastewater .

Sensor features

  • Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements.
  • International drinking water approvals. Degree of protection IP68 (Type 6P enclosure).

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
  • Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.

Nominal diameter range

  • DN 25 to 3000(1 to 120")

Wetted materials

  • Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
  • Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
  • Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
  • Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

Measured variables

  • Volume flow, conductivity, mass flow

Max. measurement error

  • Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
  • Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

Measuring range

  • 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)

Max. process pressure

  • PN 40, Class 300, 20K

Medium temperature range

  • Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
  • Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)

Ambient temperature range

  • Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
  • Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

Sensor housing material

  • DN 25 to 300 (1 to 12"): AlSi10Mg, coated
  • DN 25 to 2400 (1 to 90"): Carbon steel with protective varnish
  • Sensor connection housing (standard): AlSi10Mg, coated
  • Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L

Transmitter housing material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

Degree of protection

  • Compact version: IP66/67, type 4X enclosure
  • Sensor remote version (standard): IP66/67, type 4X enclosure
  • Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible

Outputs

  • 4 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Double pulse output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC

Product safety

  • CE, C-tick, EAC marking

Functional safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine approvals and certificates

  • LR approval, DNV approval, ABS approval, BV approval

Pressure approvals and certificates

  • CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • ACS, KTW/W270, NSF 61, WRAS BS 6920
show more