Electromagnetic flowmeter Promag 5W5B
Brand: Endress+HauserElectromagnetic flowmeter Promag 5W5B
Brand: Endress+Hauser
Extended
Heartbeat Technology Specs at a Glance
Measuring range:
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Medium temperature range:
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Max. process pressure:
PN 40, Class 300, 20K
Max. measurement error:
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Wetted materials:
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Field of application
Electromagnetic flowmeter
Inline version.
Application: Dedicated to the
measurement of industrial or municipal
water and wastewater.
International drinking water approvals.
Installation length: DVGW/ISO conform.
Remote version.
4-line display, touch control.
Specifications
Brand
Industry
- Water, Wastewater & Waste
- Power & Energy
- Mining, Minerals & Metals
Product Family
- Promag
Liquids
Product headline
- Specialist for demanding water and wastewater applications as remote version with up to 4 I/Os.
- Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
- Dedicated to the measurement of industrial or municipal water and wastewater .
Sensor features
- Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements.
- International drinking water approvals. Degree of protection IP68 (Type 6P enclosure).
Transmitter features
- Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
- Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range
- DN 25 to 3000(1 to 120")
Wetted materials
- Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
- Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
- Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
- Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Measured variables
- Volume flow, conductivity, mass flow
Max. measurement error
- Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
- Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Measuring range
- 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Max. process pressure
- PN 40, Class 300, 20K
Medium temperature range
- Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
- Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Ambient temperature range
- Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
- Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
- DN 25 to 300 (1 to 12"): AlSi10Mg, coated
- DN 25 to 2400 (1 to 90"): Carbon steel with protective varnish
- Sensor connection housing (standard): AlSi10Mg, coated
- Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L
Transmitter housing material
- AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree of protection
- Compact version: IP66/67, type 4X enclosure
- Sensor remote version (standard): IP66/67, type 4X enclosure
- Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3
Display/Operation
- 4-line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
Outputs
- 4 outputs:
- 4-20 mA HART (active/passive)
- 4-20 mA (active/passive)
- Pulse/frequency/switch output (active/passive)
- Double pulse output (active/passive)
- Relay output
Inputs
- Status input
- 4-20 mA input
Digital communication
- HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply
- DC 24 V
- AC 100 to 230 V
- AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
- ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC
Product safety
- CE, C-tick, EAC marking
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates
- LR approval, DNV approval, ABS approval, BV approval
Pressure approvals and certificates
- CRN
Material certificates
- 3.1 material
Hygienic approvals and certificates
- ACS, KTW/W270, NSF 61, WRAS BS 6920