Electromagnetic flowmeter Magphant DTI200

Brand: Endress+Hauser

Electromagnetic flowmeter Magphant DTI200

Brand: Endress+Hauser

Forberg Smith, Endress+Hauser's exclusive USA representative in:
KY MI OH PA  Parts of WI WV 

Specs at a Glance

Medium temperature range:
-20 to +120°C
(-4 to +248°F)
Max. process pressure:
0 to 16 bar abs
Max. measurement error:
2%
Measuring range:
0 to 56'550 m3/h
Wetted materials:
1.4435/316L

Specifications

Industry

  • Water, Wastewater & Waste

Product Family

  • Magphant

Liquids

Product headline

  • .

Sensor features

  • High plant availability – reliable flow information. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts. Compact, space-saving design. Nominal diameter: DN 15 to 2000 (½ to 80").

Transmitter features

  • Process safety – device self-monitoring and reliable monitoring even with empty piping. Product safety – integrated testing to check correct functioning of the electronics. Easy operation – potentiometer setting of full-scale value. Switch point setting via rotary switch. Current output and relay output.

Nominal diameter range

  • DN15 to DN2000
  • 1/2" to 80"

Wetted materials

  • 1.4435/316L

Measured variables

  • Volume flow

Max. measurement error

  • 2%

Measuring range

  • 0 to 56'550 m3/h

Max. process pressure

  • 0 to 16 bar abs

Medium temperature range

  • -20 to +120°C
  • (-4 to +248°F)

Ambient temperature range

  • -20...60 °C (-4 to 140°F)

Sensor housing material

  • Die-cast aluminium, epoxy powder coated

Degree of protection

  • IP 66 / NEMA 4X / Type 4X

Display/Operation

  • Test function

Outputs

  • 4 to 20 mA
  • Relay

Inputs

  • None

Power supply

  • 24 V DC (20...30 V DC)

Hazardous area approvals

  • FM
  • CSA

Product safety

  • CE, EAC
show more