Electromagnetic flowmeter Promag 5P1B

Brand: Endress+Hauser

Electromagnetic flowmeter Promag 5P1B

Brand: Endress+Hauser

Forberg Smith, Endress+Hauser's exclusive USA representative in:
KY MI OH PA  Parts of WI WV 

Extended Extended
Heartbeat Technology Heartbeat Technology

Specs at a Glance

Measuring range:
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
Max. measurement error:
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s
Medium temperature range:
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
Wetted materials:
Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803)
Max. process pressure:
PN 40, Class 300, 20K

Field of application

Electromagnetic flowmeter
Inline version.
Dedicated to chemical and process
applications with corrosive liquids and
high medium temperatures.
Wide variety of electrode materials.
Liner: PTFE, PFA.
Transmitter: Robust, ultra-compact.

Specifications

Industry

  • Water, Wastewater & Waste

Product Family

  • Promag

Liquids

Product headline

  • The flowmeter for highest medium temperatures with an ultra-compact transmitter.
  • Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

Sensor features

  • Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
  • Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA.

Transmitter features

  • Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
  • Robust, ultra-compact transmitter housing. Local display available.

Nominal diameter range

  • DN 15 to 600 (½ to 24")

Wetted materials

  • Liner: PFA, PTFE
  • Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
  • Duplex 1.4462 (UNS S31803)

Measured variables

  • Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity

Max. measurement error

  • Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
  • Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s

Measuring range

  • 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)

Max. process pressure

  • PN 40, Class 300, 20K

Medium temperature range

  • Liner material PFA: –20 to +150 °C (–4 to +302 °F)
  • Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
  • Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

Ambient temperature range

  • Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
  • Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

Sensor housing material

  • DN 15 to 300 (½ to 12"): AlSi10Mg, coated
  • DN 350 to 600 (14 to 24"): Carbon steel with protective varnish

Transmitter housing material

  • AlSi10Mg, coated

Degree of protection

  • IP66/67, type 4X enclosure

Display/Operation

  • 4‐line backlit display available (no local operation)
  • Configuration via web browser and operating tools possible

Outputs

  • 4‐20 mA HART (active)
  • Pulse/frequency/switch output (passive)

Inputs

  • None

Digital communication

  • HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET

Power supply

  • DC 20 to 30 V

Hazardous area approvals

  • ATEX, IECEx, cCSAus, INMETRO

Other approvals and certificates

    Product safety

    • CE, C-Tick

    Metrological approvals and certificates

    • Calibration performed on accredited calibration facilities (acc. to ISO/IEC
    • 17025)
    • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

    Marine approvals and certificates

    • LR approval, DNV approval, ABS approval, BV approval

    Pressure approvals and certificates

    • PED, CRN

    Material certificates

    • 3.1 material

    Hygienic approvals and certificates

    • Drinking water approval: ACS, NSF 61, WRAS
    show more