pH Sensors & Transmitters

Products for high-quality pH measurement in all industries.

1 - 48 of 80 Products
Analog pH Sensor Orbipore CPS91
Endress+Hauser
cps91 spitze.png
Request Information
Multiparameter Handheld Liquiline Mobile CML18
Endress+Hauser
Liquiline Mobile CML18_s_stehend_001.png
Lean Lean
Request Information
Digital pH Sensor Memosens CPL51E
Endress+Hauser
CPL51E_s_20.01._001.png
Fundamental Fundamental
Request Information
Multichannel Multiparameter Software Memobase Plus CYZ71D
Endress+Hauser
CYZ71D.png
Request Information
Digital Non-Glass pH Sensor Ceramax CPS341D
Endress+Hauser
cps341d_ceramax gerade.png
Extended Extended
Request Information
Immersion Assembly Dipfit CPA140
Endress+Hauser
CPA140_front.png
Request Information
Digital pH Sensor Memosens CPS71E
Endress+Hauser
CPS71E-pH-sensor.png
Extended Extended
Request Information
Process Assembly Unifit CPA842
Endress+Hauser
CPA842_front_with cable protection.png
Request Information
Combined pH/ORP Sensor Memosens CPS76E
Endress+Hauser
CPS76E-combined-pH-ORP-sensor.png
Extended Extended
Request Information
Flow Assembly for Multi-Parameter Measurements Flowfit CYA27
Endress+Hauser
Flow assembly for multi-parameter measurements Flowfit CYA27
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA871
Endress+Hauser
cpa871_peek_immersion_chamber_manual.png
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA875
Endress+Hauser
CPA875_pneumatic_measuring_position.png
Request Information
Digital pH Sensor Memosens CPS11E
Endress+Hauser
CPS11E-pH-sensor-ion-trap-ex-version-straight.png
Extended Extended
Request Information
Digital Service Tool Memocheck CYP02E
Endress+Hauser
Digital service tool Memocheck CYP02E
Request Information
Digital pH Sensor Orbisint CPS11D
Endress+Hauser
CPS11D_Ex_front.png
Extended Extended
Request Information
Digital pH Sensor Memosens CPL59E
Endress+Hauser
Memosens CPL59E.png
Request Information
1-Channel Transmitter Liquiline CM14
Endress+Hauser
cm14_12_04_2011_007_pH.png
Fundamental Fundamental
Request Information
Analog pH Sensor Ceraliquid CPS41
Endress+Hauser
cps41 - mit TOP68.png
Request Information
Flow Assembly Flowfit CPA240
Endress+Hauser
CPA240.png
Request Information
Process Assembly Ecofit CPA640
Endress+Hauser
CPA640.png
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA474
Endress+Hauser
CPA474.png
Request Information
Cleaning Unit Cleanfit Control CYC25
Endress+Hauser
Cleaning unit Cleanfit Control CYC25
Request Information
Analog pH Sensor Ceratex CPS31
Endress+Hauser
CPS31_pH_sensor_angular.png
Request Information
Flow Assembly Flowfit CYA21
Endress+Hauser
CYA21_Durchflussarmatur 71042404_g_001.png
Request Information
pH Buffer CPY20
Endress+Hauser
CPY20 pH buffers.png
Request Information
Liquiline Edge Module CYY7
Endress+Hauser
Liquiline Edge Module CYY7
Extended Extended
Request Information
Digital Extension Cable Memosens CYK11
Endress+Hauser
Digital extension cable CYK11
Request Information
Digital pH Sensor Memosens CPS61E
Endress+Hauser
CPS61E-digital-ph-sensor.png
Extended Extended
Request Information
Digital Service and Qualification Tool Memocheck Sim CYP03D
Endress+Hauser
Digital service and qualification tool Memocheck Sim CYP03D
Request Information
Memosens Analog Converter CYM17
Endress+Hauser
Converterbox CYM17_s_001.png
Request Information
4-Channel Transmitter Liquiline CM444R
Endress+Hauser
CM444R.png
Extended Extended
Request Information
Digital pH Sensor Memosens CPL57E
Endress+Hauser
Memosens CPL57E.png
Request Information
1-Channel Transmitter Liquiline Compact CM82
Endress+Hauser
Liquiline Compact CM82_angular.png
Request Information
4-Channel Transmitter Liquiline CM444
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Flow Assembly CYA680
Endress+Hauser
Flow assembly CYA680
Request Information
1-/2-Channel Transmitter Liquiline CM442
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
pH/ORP Transmitter Liquisys CPM253
Endress+Hauser
CPM253.png
Request Information
8-Channel Transmitter Liquiline CM448R
Endress+Hauser
CM448R.png
Extended Extended
Request Information
Immersion Assembly Flexdip CYA112
Endress+Hauser
CYA112_Rendering_2.png
Request Information
Digital Combined pH/ORP Sensor Memosens CPS16E
Endress+Hauser
CPS16E-combined-pH_ORP-sensor.png
Extended Extended
Request Information
Analog pH Sensor Ceragel CPS71
Endress+Hauser
cps71-pH-sensor-front.png
Request Information
pH/ORP Transmitter Liquisys CPM223
Endress+Hauser
CPM223.png
Request Information
Digital pH Sensor Orbipac CPF81D
Endress+Hauser
CPF81D-pH-sensor-angular.png
Request Information
Digital Combined pH/ORP Sensor Memosens CPS96E
Endress+Hauser
CPS96E-combined-pH-ORP-sensor-Beauty.png
Extended Extended
Request Information
Immersion Assembly Dipfit CPA111
Endress+Hauser
CPA111_front.png
Request Information
Multichannel Transmitter Liquiline CM44P
Endress+Hauser
Liquiline_CM44P_AU.png
Extended Extended
Request Information
Flow Assembly Flowfit CPA25
Endress+Hauser
Flow assembly Flowfit CPA25
Lean Lean
Request Information
Digital pH Sensor Memosens CPS31E
Endress+Hauser
CPS31E-pH-sensor-salt-storage.png
Extended Extended
Request Information

pH Sensors & Transmitters

pH measurement determines hydrogen ion activity and is foundational for controlling reactions, solubility, corrosion, and biological performance. Process pH sensors typically use a glass electrode and reference system designed for continuous in‑situ service, paired with a transmitter that provides high‑impedance measurement, temperature compensation, diagnostics, and outputs. Sensor options vary widely to address high temperature, high pressure, abrasives, solvents, low conductivity water, and hygienic requirements.

The benefit is precise control of chemistry with minimal waste and risk. pH strongly influences coagulation, disinfection efficacy, scaling tendency, metal precipitation, and biological nutrient removal. Stable pH control reduces chemical consumption, improves product consistency, protects equipment, and supports regulatory compliance. Continuous pH trending also helps diagnose upstream disturbances and mixing issues that would be missed by intermittent testing.

Applications include neutralization systems for industrial wastewater, coagulation and softening control in water treatment, CIP chemical verification, fermentation and bioprocess control, and chemical manufacturing reactions where yield depends on pH windows. pH is also critical in boiler and cooling water chemistry programs to control corrosion and deposition. In mining and hydrometallurgy, pH drives leaching, precipitation, and thickening behavior.

Implementation success depends on selecting the right sensor construction and ensuring a maintainable installation. Retractable assemblies enable safe sensor removal for cleaning and calibration without stopping the process. Proper location avoids stagnant zones, air entrainment, and extreme velocity that can damage electrodes. Reference junction selection and electrolyte strategy should match fouling potential and chemical exposure to minimize drift and junction poisoning.

Operational best practices include routine calibration with appropriate buffers, cleaning protocols matched to fouling type, and tracking slope/offset trends to predict end-of-life. Transmitters with sensor diagnostics and event logs improve measurement confidence and simplify audits. When pH is coordinated with ORP, conductivity, and flow data, control strategies become more robust, reducing overshoot and improving overall process stability.

Forberg Smith, an exclusive authorized representative of sales and service for Endress+Hauser.