pH Sensors & Transmitters

Products for high-quality pH measurement in all industries.

1 - 48 of 80 Products
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request Information
Dipfit CPA111
Endress+Hauser
Dipfit CPA111
Request Information
pH sensor Memosens CPS31E
Endress+Hauser
pH sensor Memosens CPS31E
Extended Extended
Request Information
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request Information
Flowfit CYA21
Endress+Hauser
Flowfit CYA21
Request Information
pH sensor Memosens CPL57E
Endress+Hauser
pH sensor Memosens CPL57E
Request Information
Flowfit CPA25
Endress+Hauser
Flowfit CPA25
Lean Lean
Request Information
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request Information
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request Information
Memosens CPS16E
Endress+Hauser
Memosens CPS16E
Extended Extended
Request Information
In-line Photometer CYA680
Endress+Hauser
In-line Photometer CYA680
Request Information
Chemoclean CYR10B
Endress+Hauser
Chemoclean CYR10B
Request Information
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request Information
Memobase CYZ71D
Endress+Hauser
Memobase CYZ71D
Request Information
Flowfit CPA240
Endress+Hauser
Flowfit CPA240
Request Information
Hand held CYM290
Endress+Hauser
Hand held CYM290
Request Information
Digital measuring cable Measuring cable CYK10
Endress+Hauser
Digital measuring cable Measuring cable CYK10
Request Information
pH/ORP sensor Memosens CPS96E
Endress+Hauser
pH/ORP sensor Memosens CPS96E
Extended Extended
Request Information
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request Information
Memosens CPS76E
Endress+Hauser
Memosens CPS76E
Extended Extended
Request Information
pH sensor Memosens CPL59E
Endress+Hauser
pH sensor Memosens CPL59E
Request Information
Ceramax CPS341D
Endress+Hauser
Ceramax CPS341D
Extended Extended
Request Information
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request Information
Digital measuring cable Memobase CYK20
Endress+Hauser
Digital measuring cable Memobase CYK20
Request Information
Converter CYM17
Endress+Hauser
Converter CYM17
Request Information
Transmitter Liquiline, 4-wire CM14
Endress+Hauser
Transmitter Liquiline, 4-wire CM14
Fundamental Fundamental
Request Information
Ceratex CPS31
Endress+Hauser
Ceratex CPS31
Request Information
Transmitter Liquiline, 2-wire CM42
Endress+Hauser
Transmitter Liquiline, 2-wire CM42
Extended Extended
Request Information
Digital pH sensor Memosens Wave CPL51E
Endress+Hauser
Digital pH sensor Memosens Wave CPL51E
Fundamental Fundamental
Request Information
pH buffer Buffer solution CPY20
Endress+Hauser
pH buffer Buffer solution CPY20
Request Information
Orbipore CPS91
Endress+Hauser
Orbipore CPS91
Request Information
Flexdip CYH112
Endress+Hauser
Flexdip CYH112
Request Information
Cleanfit CPA875
Endress+Hauser
Cleanfit CPA875
Request Information
Liquisys CPM253
Endress+Hauser
Liquisys CPM253
Request Information
Cleanfit CPA871
Endress+Hauser
Cleanfit CPA871
Request Information
Memocheck CYP02E
Endress+Hauser
Memocheck CYP02E
Request Information
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request Information
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request Information
Transmitter Liquiline, 2-wire CM82
Endress+Hauser
Transmitter Liquiline, 2-wire CM82
Request Information
Memosens CPS71E
Endress+Hauser
Memosens CPS71E
Extended Extended
Request Information
Digital pH sensor Orbisint CPS11D
Endress+Hauser
Digital pH sensor Orbisint CPS11D
Extended Extended
Request Information
Memosens CPS47E
Endress+Hauser
Memosens CPS47E
Extended Extended
Request Information
Ceraliquid CPS41
Endress+Hauser
Ceraliquid CPS41
Request Information
Orbipac CPF81
Endress+Hauser
Orbipac CPF81
Request Information
Ceragel CPS71
Endress+Hauser
Ceragel CPS71
Request Information
Cleanfit CPA472D
Endress+Hauser
Cleanfit CPA472D
Request Information
Hand held CYM291
Endress+Hauser
Hand held CYM291
Request Information
Multi parameter measuring device Hand held CML18
Endress+Hauser
Multi parameter measuring device Hand held CML18
Lean Lean
Request Information

pH Sensors & Transmitters

pH measurement determines hydrogen ion activity and is foundational for controlling reactions, solubility, corrosion, and biological performance. Process pH sensors typically use a glass electrode and reference system designed for continuous in‑situ service, paired with a transmitter that provides high‑impedance measurement, temperature compensation, diagnostics, and outputs. Sensor options vary widely to address high temperature, high pressure, abrasives, solvents, low conductivity water, and hygienic requirements.

The benefit is precise control of chemistry with minimal waste and risk. pH strongly influences coagulation, disinfection efficacy, scaling tendency, metal precipitation, and biological nutrient removal. Stable pH control reduces chemical consumption, improves product consistency, protects equipment, and supports regulatory compliance. Continuous pH trending also helps diagnose upstream disturbances and mixing issues that would be missed by intermittent testing.

Applications include neutralization systems for industrial wastewater, coagulation and softening control in water treatment, CIP chemical verification, fermentation and bioprocess control, and chemical manufacturing reactions where yield depends on pH windows. pH is also critical in boiler and cooling water chemistry programs to control corrosion and deposition. In mining and hydrometallurgy, pH drives leaching, precipitation, and thickening behavior.

Implementation success depends on selecting the right sensor construction and ensuring a maintainable installation. Retractable assemblies enable safe sensor removal for cleaning and calibration without stopping the process. Proper location avoids stagnant zones, air entrainment, and extreme velocity that can damage electrodes. Reference junction selection and electrolyte strategy should match fouling potential and chemical exposure to minimize drift and junction poisoning.

Operational best practices include routine calibration with appropriate buffers, cleaning protocols matched to fouling type, and tracking slope/offset trends to predict end-of-life. Transmitters with sensor diagnostics and event logs improve measurement confidence and simplify audits. When pH is coordinated with ORP, conductivity, and flow data, control strategies become more robust, reducing overshoot and improving overall process stability.

Forberg Smith, an exclusive authorized representative of sales and service for Endress+Hauser.