Heavy duty (old thermometer line) T53
Brand: Endress+HauserHeavy duty (old thermometer line) T53
Brand: Endress+Hauser
Extended Specs at a Glance
Operating temperature range:
Type T:
-270 °C ...400 °C
(-454 °F ...752 °F)
Type J:
-210 °C ...1200 °C
(-346 °F ...2.192 °F)
Type E:
-270 °C ...1.000 °C
(-454 °F ...1.832 °F)
Type K:
-270 °C ...1.372 °C
(-454 °F ...2.500 °F)
Type N:
-270 °C ...1.300 °C
(-454 °F ...2.372 °F)
-270 °C ...400 °C
(-454 °F ...752 °F)
Type J:
-210 °C ...1200 °C
(-346 °F ...2.192 °F)
Type E:
-270 °C ...1.000 °C
(-454 °F ...1.832 °F)
Type K:
-270 °C ...1.372 °C
(-454 °F ...2.500 °F)
Type N:
-270 °C ...1.300 °C
(-454 °F ...2.372 °F)
Max. process pressure (static):
Standard acc. to ASTM E-230
Special acc. to ASTM E-230
Special acc. to ASTM E-230
Accuracy:
Standard acc. to ASTM E-230
Special acc. to ASTM E-230
Special acc. to ASTM E-230
Max. immersion length on request:
up to 22.5" (571 mm)
others on request
others on request
Response time:
depending on configuration
63% rt = 15,0 s
63% rt = 15,0 s
Field of application
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust thermowells and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.
Key Benefits
- FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety
- One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications
- Remove and install straight out of the box!
- All iTEMP transmitters provide long term stability ≤0.05% per year
Specifications
Brand
Industry
- Mining, Minerals & Metals
- Oil & Gas
- Other industries
Thermometer
Characteristic / Application
- Explosion Proof US style
- modular temperature assembly
- for heavy duty applications
- threaded process connection
- with extension
- incl. thermowell
Thermowell / protection tube
- bar stock (drilled)
Insert / probe
- mineral insulated (MI), flexible
Outer diameter protection tube / Insert
- 0,63'' ...1,31'' (15,88 mm ... 33,40 mm)
Max. immersion length on request
- up to 22.5" (571 mm)
- others on request
Material protection tube/ thermowell
- 316/316L
- A105
- others on request
Optional coating
- available on request
Process connection
- male thread:
- NPT1/2"
- NPT3/4"
- NPT1"
- weld in version
- socket weld version
Tip shape
- stepped
- tapered
Surface roughness Ra
- 32 μin (0.80 μm)
Operating temperature range
- Type T:
- -270 °C ...400 °C
- (-454 °F ...752 °F)
- Type J:
- -210 °C ...1200 °C
- (-346 °F ...2.192 °F)
- Type E:
- -270 °C ...1.000 °C
- (-454 °F ...1.832 °F)
- Type K:
- -270 °C ...1.372 °C
- (-454 °F ...2.500 °F)
- Type N:
- -270 °C ...1.300 °C
- (-454 °F ...2.372 °F)
Max. process pressure (static)
- Standard acc. to ASTM E-230
- Special acc. to ASTM E-230
Accuracy
- Standard acc. to ASTM E-230
- Special acc. to ASTM E-230
Response time
- depending on configuration
- 63% rt = 15,0 s
Integration head transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
- FM XP
- CSA XP
- FM/CSA XP
- CSA GP
Certification
- SIL (transmitter only)