Electromagnetic flowmeter Promag D 5DBB

Brand: Endress+Hauser

Electromagnetic flowmeter Promag D 5DBB

Brand: Endress+Hauser

Forberg Smith, Endress+Hauser's exclusive USA representative in:
KY MI OH PA  Parts of WI WV 

Lean Lean
Heartbeat Technology Heartbeat Technology

Specs at a Glance

Measuring range:
9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
Max. measurement error:
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Max. process pressure:
PN 16, Class 150, 10K
Wetted materials:
Liner material polyamide: 0 to +60°C (+32 to +140°F)
Electrodes: 1.4435 (316L)
Medium temperature range:
Liner material polyamide: 0 to +60°C (+32 to +140°F)

Field of application

Proline Promag D 10 is a wafer flowmeter designed for water applications where space is constrained. Versions with touch screen or the Endress+Hauser SmartBlue app that can easily be operated. Optional Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

Key Benefits

  • Easy mounting – space-saving wafer or threaded process connection
  • Simple commissioning – wizard-guided parameterization in advance or in the field saves time
  • Easy operation – optional LC display or Bluetooth connection guarantee intuitive handling
  • Maintenance-free – no moving parts

Specifications

Target Customer

  • Waste water treatment plants
  • Drinking water producers

Product Family

  • Promag

Liquids

Product headline

  • Highly cost-effective wafer flowmeter with easy-to-use operation concept.
  • For basic water applications, optimized for limited space and plastic pipe installations.

Sensor features

  • Easy, fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
  • Short face-to-face length and low weight. Integrated ground disks made of stainless steel. International drinking water approvals.

Transmitter features

  • Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
  • 2-line display with push buttons. Device as compact or remote version. HART.

Nominal diameter range

  • DN 25 to 100 (1 to 4")

Wetted materials

  • Liner material polyamide: 0 to +60°C (+32 to +140°F)
  • Electrodes: 1.4435 (316L)

Measured variables

  • Volume flow, mass flow

Max. measurement error

  • Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)

Measuring range

  • 9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)

Max. process pressure

  • PN 16, Class 150, 10K

Medium temperature range

  • Liner material polyamide: 0 to +60°C (+32 to +140°F)

Ambient temperature range

  • -40 to 60°C (-40 to 140°F)

Sensor housing material

  • DN 25 to 100 (1 to 12"): AlSi10Mg, coated

Transmitter housing material

  • Polycarbonat; AlSi10Mg, coated

Degree of protection

  • Compact version: IP66/67, type 4X enclosure
  • Sensor remote version (standard): IP66/67, type 4X enclosure

Display/Operation

  • LCD display with touch & auto rotate

Outputs

  • 4-20 mA HART (active/passive), Pulse/frequency/switch output
  • Modbus RS485, 4-20 mA

Digital communication

  • HART, MODBUS RS485

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • CSA, GP

Product safety

  • Product safety

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Hygienic approvals and certificates

  • Hygienic approvals and certificates

No Videos