Thermal Mass Flowmeter t-mass I 6I3B
Brand: Endress+HauserThermal Mass Flowmeter t-mass I 6I3B
Brand: Endress+Hauser
Extended
Heartbeat Technology Specs at a Glance
Max. measurement error:
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Wetted materials:
Materials for insertion tube
Stainless steel, 1.4404 (316/316L)
Process connections, process coupling
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
Stainless steel, 1.4404 (316/316L)
Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)
Clamping rings
PEEK
PVDF
1.4404 (316/316L)
Flat ring seal
EPDM
FKM
Stainless steel, 1.4404 (316/316L)
Process connections, process coupling
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
Stainless steel, 1.4404 (316/316L)
Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)
Clamping rings
PEEK
PVDF
1.4404 (316/316L)
Flat ring seal
EPDM
FKM
Measuring range:
20 to 733501 kg/h (44 to 1669340 lb/h)
Medium temperature range:
-40 °C to +180°C (-40 °F to +356°F)
Max. process pressure:
-0.5 to 20 bar_g (-7.25 to 290 psi_g)
Field of application
Thermal mass flowmeter
Insertion version.
Application: Measurement of utility and
process gases as well as gas mixtures in
circular piping or rectangular ducts.
High operable flow range: up to 1000:1.
Flexible installation.
Medium temp.: up to +180 oC (356 oF).
Compact dual-compartment housing.
Specifications
Brand
Product Family
- T-mass
Gas
Product headline
- Insertion flowmeter with long-term stability and a compact, easily accessible transmitter.
- Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof.
- Measurement of utility and process gases as well as gas mixtures in circular piping or rectangular ducts.
Sensor features
- High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Flexible installation – suitable for large dimensional range and circular pipes or rectangular ducts.
- Insertion version for DN 80 to 1500 (3 to 60"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2.
Transmitter features
- Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
- Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range
- DN 80 to 1500 (3 to 60")
Wetted materials
- Materials for insertion tube
- Stainless steel, 1.4404 (316/316L)
- Process connections, process coupling
- Sensing element
- Unidirectional
- Alloy C22, 2.4602 (UNS N06022);
- Bidirectional
- Reverse flow detection
- Clamping rings
- PEEK
- PVDF
- 1.4404 (316/316L)
- Flat ring seal
- EPDM
- FKM
Measured variables
- Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density
Max. measurement error
- Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Measuring range
- 20 to 733501 kg/h (44 to 1669340 lb/h)
Max. process pressure
- -0.5 to 20 bar_g (-7.25 to 290 psi_g)
Medium temperature range
- -40 °C to +180°C (-40 °F to +356°F)
Ambient temperature range
- -40 to 60°C (-40 to 140°F)
- Optional:
- Transmitter: -50 to 60°C (-50 to 140°F),
- Sensor: -60 to 60°C (-60 to 140°F)
Transmitter housing material
- Aluminium, AlSi10Mg, coated
- Polycarbonate
Degree of protection
- IP66/67, Type 4X enclosure
Display/Operation
- 4-line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
- Remote display available
Outputs
- 3 outputs:
- 4-20 mA HART (active/passive)
- 4-20 mA (active/passive)
- Pulse/frequency/switch output (active/passive)
- Relay output
Inputs
- Status input
- 4-20 mA input
Digital communication
- HART, Modbus RS485
Power supply
- DC 24V
- AC 100 to 240V
Hazardous area approvals
- ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC
Product safety
- CE, C-tick
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Pressure approvals and certificates
- CRN
Material certificates
- 3.1 material
- NACE MR0175/MR0103