Promass S 8S3B

Brand: Endress+Hauser

Promass S 8S3B

Brand: Endress+Hauser

Forberg Smith, Endress+Hauser's exclusive USA representative in:
KY MI OH PA  Parts of WI WV 

Xpert Xpert
Heartbeat Technology Heartbeat Technology

Specs at a Glance

Medium temperature range:
–50 to +150 °C (–58 to +302 °F)
Max. measurement error:
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
Max. process pressure:
PN 40, Class 150, 20K
Measuring range:
0 to 70 000 kg/h (0 to 2570 lb/min)
Wetted materials:
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)

Field of application

Promass S is at the forefront in hygienic design and dedicated to applications in the food and beverage industry requiring optimal cleanability. The self‐drainable single-tube system ensures careful treatment of fluids. With its compact transmitter Promass S 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables process safety at all times.

Measuring principle operates independently of physical fluid properties such as viscosity or density

Dedicated to applications requiring optimal cleanability under hygienic conditions.

Device properties

Large range of hygienic process connections

3-A and EHEDG conform

Fast recovery from CIP/SIP

Compact dual-compartment housing with up to 3 I/Os

Backlit display with touch control and WLAN access

Remote display available

Key Benefits

  • Increased process safety – easily cleanable and fully self-drainable tube design
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in-/outlet run needs
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology

Specifications

Industry

  • Food & Beverage
  • Life Science

Product Family

  • Promass

Density

Product Headline

  • Easy‐to‐clean, self‐drainable single‐tube system with a compact, easily accessible transmitter.
  • Dedicated to applications requiring optimal cleanability under hygienic conditions.

Density/Concentration

Product headline

  • Easy‐to‐clean, self‐drainable single‐tube system with a compact, easily accessible transmitter.
  • Dedicated to applications requiring optimal cleanability under hygienic conditions.

Sensor features

  • Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
  • Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

Nominal diameter range

  • DN 8 to 50 (⅜ to 2")

Wetted materials

  • Measuring tube: 1.4435 (316L)
  • Connection: 1.4435 (316L); 1.4404 (316/316L)"

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

  • Mass flow (liquid): ±0.10 %
  • Volume flow (liquid): ±0.10 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 70 000 kg/h (0 to 2570 lb/min)

Max. process pressure

  • PN 40, Class 150, 20K

Medium temperature range

  • –50 to +150 °C (–58 to +302 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301 (304), corrosion resistant

Transmitter housing material

  • AlSi10Mg, coated; stainless steel for hygenic transmitter design

Degree of protection

  • IP66/67, type 4X enclosure
  • IP69

Display/Operation

  • 4-line backlit display with touch + control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA WirelessHART
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Double pulse output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product safety

  • CE, C-tick, EAC marking

Functional safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure approvals and certificates

  • PED, CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • 3-A, EHEDG, cGMP

Gas

Sensor features

  • Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.

Hygienic approvals and certificates

  • cGMP

Liquids

Product headline

  • Easy‐to‐clean, self‐drainable single‐tube system with a compact, easily accessible transmitter.
  • Dedicated to applications requiring optimal cleanability under hygienic conditions.

Sensor features

  • Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
  • Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

Nominal diameter range

  • DN 8 to 50 (⅜ to 2")

Wetted materials

  • Measuring tube: 1.4435 (316L)
  • Connection: 1.4435 (316L); 1.4404 (316/316L)

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

  • Mass flow (liquid): ±0.10 %
  • Volume flow (liquid): ±0.10 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 70 000 kg/h (0 to 2570 lb/min)

Max. process pressure

  • PN 40, Class 150, 20K

Medium temperature range

  • –50 to +150 °C (–58 to +302 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301 (304), corrosion resistant

Transmitter housing material

  • AlSi10Mg, coated; stainless steel for hygenic transmitter design

Degree of protection

  • IP66/67, type 4X enclosure
  • IP69

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA WirelessHART
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Double pulse output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product safety

  • CE, C-tick, EAC marking

Functional safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure approvals and certificates

  • PED, CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • 3-A, EHEDG, cGMP
show more