ORP Sensors & Transmitters

Products for effective ORP measurement in all industries.

1 - 48 of 51 Products
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request Information
Dipfit CPA111
Endress+Hauser
Dipfit CPA111
Request Information
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request Information
Flowfit CYA21
Endress+Hauser
Flowfit CYA21
Request Information
Flowfit CPA25
Endress+Hauser
Flowfit CPA25
Lean Lean
Request Information
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request Information
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request Information
Memosens CPS16E
Endress+Hauser
Memosens CPS16E
Extended Extended
Request Information
In-line Photometer CYA680
Endress+Hauser
In-line Photometer CYA680
Request Information
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request Information
Flowfit CPA240
Endress+Hauser
Flowfit CPA240
Request Information
pH/ORP sensor Memosens CPS96E
Endress+Hauser
pH/ORP sensor Memosens CPS96E
Extended Extended
Request Information
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request Information
Memosens CPS76E
Endress+Hauser
Memosens CPS76E
Extended Extended
Request Information
Memosens CPS42E
Endress+Hauser
Memosens CPS42E
Request Information
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request Information
Transmitter Liquiline, 4-wire CM14
Endress+Hauser
Transmitter Liquiline, 4-wire CM14
Fundamental Fundamental
Request Information
Orbipac CPF82D
Endress+Hauser
Orbipac CPF82D
Request Information
Transmitter Liquiline, 2-wire CM42
Endress+Hauser
Transmitter Liquiline, 2-wire CM42
Extended Extended
Request Information
Ceraliquid CPS42D
Endress+Hauser
Ceraliquid CPS42D
Request Information
pH buffer Buffer solution CPY20
Endress+Hauser
pH buffer Buffer solution CPY20
Request Information
Flexdip CYH112
Endress+Hauser
Flexdip CYH112
Request Information
Orbipac CPF82
Endress+Hauser
Orbipac CPF82
Request Information
Cleanfit CPA875
Endress+Hauser
Cleanfit CPA875
Request Information
Liquisys CPM253
Endress+Hauser
Liquisys CPM253
Request Information
Cleanfit CPA871
Endress+Hauser
Cleanfit CPA871
Request Information
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request Information
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request Information
Transmitter Liquiline, 2-wire CM82
Endress+Hauser
Transmitter Liquiline, 2-wire CM82
Request Information
Ceragel CPS72D
Endress+Hauser
Ceragel CPS72D
Request Information
Memosens CPS62E
Endress+Hauser
Memosens CPS62E
Extended Extended
Request Information
Memosens CPF82E
Endress+Hauser
Memosens CPF82E
Extended Extended
Request Information
Orbisint CPS12D
Endress+Hauser
Orbisint CPS12D
Request Information
Memosens CPS72E
Endress+Hauser
Memosens CPS72E
Extended Extended
Request Information
Ceragel CPS72
Endress+Hauser
Ceragel CPS72
Request Information
Cleanfit CPA472D
Endress+Hauser
Cleanfit CPA472D
Request Information
Multi parameter measuring device Hand held CML18
Endress+Hauser
Multi parameter measuring device Hand held CML18
Lean Lean
Request Information
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request Information
Cleanfit CPA473
Endress+Hauser
Cleanfit CPA473
Request Information
Liquisys CPM223
Endress+Hauser
Liquisys CPM223
Request Information
Memosens CPS92E
Endress+Hauser
Memosens CPS92E
Extended Extended
Request Information
Unifit CPA842
Endress+Hauser
Unifit CPA842
Request Information
Ecofit CPA640
Endress+Hauser
Ecofit CPA640
Request Information
Dipfit CPA140
Endress+Hauser
Dipfit CPA140
Request Information
Cleanfit CPA474
Endress+Hauser
Cleanfit CPA474
Request Information
Redox sensor Memosens CPS12E
Endress+Hauser
Redox sensor Memosens CPS12E
Extended Extended
Request Information
Orbipore CPS92D
Endress+Hauser
Orbipore CPS92D
Request Information
Cleanfit CPA450
Endress+Hauser
Cleanfit CPA450
Request Information

ORP Sensors & Transmitters

Oxidation-reduction potential (ORP) measurement indicates the electron activity of a solution, reflecting its tendency to oxidize or reduce. ORP sensors use a noble metal measuring electrode and a reference system to produce a millivolt signal that changes with redox conditions. A transmitter conditions the signal, provides temperature input if required, and outputs a stable value for monitoring, alarming, or control.

The value of ORP is its ability to summarize complex chemistry into a practical control variable. In many processes, a single ORP setpoint can maintain the desired oxidizing or reducing environment, making it useful where direct measurement of every species is impractical. ORP responds quickly to chemical addition and process shifts, supporting stable control of disinfection, dechlorination, cyanide destruction, and other redox-driven reactions.

Typical applications include wastewater treatment (anoxic zone control, denitrification monitoring, and optimization of chemical dosing), drinking water treatment (oxidant demand tracking and dechlorination), and industrial oxidation processes such as sulfide control and odor mitigation. ORP is also used in metal finishing, mining, and chemical manufacturing to monitor reduction/oxidation stages, ensuring consistent reaction endpoints and minimizing reagent overuse.

Sensor performance depends on reference stability, cleanliness, and proper installation. ORP is sensitive to coatings, scaling, and biofilm, which can slow response and shift readings. Stable flow conditions and avoidance of air entrainment improve measurement consistency. Because ORP is an indirect parameter, commissioning should include correlating ORP values with process outcomes and defining meaningful alarm limits based on real operating data.

Operationally, transmitters with diagnostics help identify electrode poisoning, reference depletion, and abnormal impedance before readings become misleading. Routine cleaning, verification, and periodic sensor replacement maintain response speed and confidence. When paired with pH, dissolved oxygen, or chlorine signals, ORP becomes even more informative for diagnosing process health and controlling complex water chemistry.

Forberg Smith, an exclusive authorized representative of sales and service for Endress+Hauser.