Conductivity Sensors & Transmitters

Products for high precision conductivity measurement in all industries.

1 - 48 of 51 Products
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request a Quote
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request a Quote
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request a Quote
Memobase CYZ71D
Endress+Hauser
Memobase CYZ71D
Request a Quote
Conductivity sensor Memosens CLL47E
Endress+Hauser
Conductivity sensor Memosens CLL47E
Request a Quote
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request a Quote
CLY421
Endress+Hauser
CLY421
Request a Quote
Hand held CYM290
Endress+Hauser
Hand held CYM290
Request a Quote
Memosens CLS82E
Endress+Hauser
Memosens CLS82E
Extended Extended
Request a Quote
Digital measuring cable Measuring cable CYK10
Endress+Hauser
Digital measuring cable Measuring cable CYK10
Request a Quote
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request a Quote
Flowfit CYA21
Endress+Hauser
Flowfit CYA21
Request a Quote
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request a Quote
Flowfit CPA25
Endress+Hauser
Flowfit CPA25
Lean Lean
Request a Quote
Transmitter Liquiline, 2-wire CM82
Endress+Hauser
Transmitter Liquiline, 2-wire CM82
Request a Quote
Digital measuring cable Memobase CYK20
Endress+Hauser
Digital measuring cable Memobase CYK20
Request a Quote
Transmitter Liquiline, 2-wire CM42
Endress+Hauser
Transmitter Liquiline, 2-wire CM42
Extended Extended
Request a Quote
Condumax CLS12
Endress+Hauser
Condumax CLS12
Request a Quote
Condumax CLS15
Endress+Hauser
Condumax CLS15
Request a Quote
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request a Quote
Memosens CLS16E
Endress+Hauser
Memosens CLS16E
Extended Extended
Request a Quote
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request a Quote
Smartec CLD132
Endress+Hauser
Smartec CLD132
Request a Quote
Hand held CYM291
Endress+Hauser
Hand held CYM291
Request a Quote
Flexdip CYH112
Endress+Hauser
Flexdip CYH112
Request a Quote
Condumax CLS19
Endress+Hauser
Condumax CLS19
Request a Quote
Condumax CLS16B
Endress+Hauser
Condumax CLS16B
Extended Extended
Request a Quote
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request a Quote
Memosens CLS21E
Endress+Hauser
Memosens CLS21E
Extended Extended
Request a Quote
In-line Photometer CYA680
Endress+Hauser
In-line Photometer CYA680
Request a Quote
Conductivity sensor Smartec CLD134
Endress+Hauser
Conductivity sensor Smartec CLD134
Extended Extended
Request a Quote
Memocheck CYP02E
Endress+Hauser
Memocheck CYP02E
Request a Quote
Conductivity sensor Indumax CLS50
Endress+Hauser
Conductivity sensor Indumax CLS50
Request a Quote
Transmitter Liquiline, 4-wire CM14
Endress+Hauser
Transmitter Liquiline, 4-wire CM14
Fundamental Fundamental
Request a Quote
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request a Quote
Indumax CLS54D
Endress+Hauser
Indumax CLS54D
Extended Extended
Request a Quote
Liquisys CLM223
Endress+Hauser
Liquisys CLM223
Request a Quote
Conductivity sensor Indumax CLS50D
Endress+Hauser
Conductivity sensor Indumax CLS50D
Extended Extended
Request a Quote
Conductivity sensor Condumax CLS21
Endress+Hauser
Conductivity sensor Condumax CLS21
Request a Quote
Dipfit CLA111
Endress+Hauser
Dipfit CLA111
Request a Quote
Memocheck CYP03D
Endress+Hauser
Memocheck CYP03D
Request a Quote
Measuring cable CYK11
Endress+Hauser
Measuring cable CYK11
Request a Quote
Condumax CLS13
Endress+Hauser
Condumax CLS13
Request a Quote
Multi parameter measuring device Hand held CML18
Endress+Hauser
Multi parameter measuring device Hand held CML18
Lean Lean
Request a Quote
Conductivity sensor Indumax CLS54
Endress+Hauser
Conductivity sensor Indumax CLS54
Request a Quote
Conductivity sensor Memosens CLS15E
Endress+Hauser
Conductivity sensor Memosens CLS15E
Extended Extended
Request a Quote
Dipfit CLA140
Endress+Hauser
Dipfit CLA140
Request a Quote
Indumax CLS52
Endress+Hauser
Indumax CLS52
Request a Quote

Conductivity Sensors & Transmitters

Conductivity measurement evaluates the ability of a liquid to carry electrical current, which correlates strongly with ionic content. Sensor technologies include contacting (electrode) designs for lower to moderate conductivity and inductive (toroidal) designs for higher conductivity, dirty service, or aggressive chemistries. A transmitter converts raw sensor signals into temperature‑compensated conductivity, resistivity, or concentration values and provides outputs for monitoring and control.

The benefit is simple, continuous insight into concentration and purity. Conductivity is widely used to control chemical dosing, detect contamination, and verify rinse endpoints. In high‑purity applications, resistivity measurement confirms low ionic contamination, supporting product quality and protecting sensitive equipment. Stable conductivity trends also function as an early warning for exchanger leaks, process upsets, and inadequate separation performance.

Applications span boiler and steam cycles, cooling systems, reverse osmosis and deionization trains, chemical concentration control, and CIP rinse verification in hygienic industries. In wastewater treatment, conductivity helps identify saline intrusions, industrial discharges, and blending opportunities. In chemical and mining services, inductive conductivity supports measurement in corrosive acids, caustics, and high‑solids slurries where electrodes would foul or degrade.

Installation and sensor selection drive performance. Contacting sensors require attention to polarization and coating effects, so cell constant selection and cleaning access matter. Inductive sensors avoid direct electrode contact and tolerate coatings better but require minimum pipe fill and careful placement away from strong electromagnetic noise sources. Temperature compensation method selection (linear, ultrapure, or custom curves) should match the process chemistry and reporting needs.

Operational excellence includes periodic validation, cleaning routines appropriate to fouling type, and trend review to catch gradual drift. Transmitters with diagnostics can flag coating, cable issues, and temperature element faults before data quality is compromised. When conductivity is paired with complementary measurements such as pH, ORP, or flow, it becomes a powerful, low‑maintenance signal for mass balance, control, and troubleshooting.

Forberg Smith, an exclusive authorized representative of sales and service for Endress+Hauser.