Teqwave D9HB

Brand: Endress+Hauser

Teqwave D9HB

Brand: Endress+Hauser

Forberg Smith, Endress+Hauser's exclusive USA representative in:
KY MI OH PA  Parts of WI WV 

Specs at a Glance

Process temperature:
0 to 120°C (32 to 248 °F)
Measuring range:
Concentration According to concentration app data sheet, maximum 0 to 100 %
Sound velocity 600 to 2000 m/s
Temperature maximum 0 to +100 °C (32 to +212 °F)
Acoustic Density 0.7 to 1.5 g/cm³
Medium temperature range:
0 to 120°C (32 to 248 °F)
Process pressure:
max. 16 bar at 20 °C (232 psi at 68 °F)
Max. measurement error:
Acoustic density: ±0.01g/cm³
Temperature: ±0.5K
Sound velocity: +-2m/s
Wetted materials:
Stainless steel1.4404 (316L)
Max. process pressure:
max. 16 bar at 20 °C (232 psi at 68 °F)

Field of application

Teqwave H is ideal for real-time liquid analysis in hygienic applications like spirits and soft drink production. End customers and equipment manufacturers value its highly accurate in situ concentration measurement and hygienic design. Teqwave reduces the operational expenditure by monitoring various measuring parameters at once. Match your Teqwave transmitter perfectly to your production needs by flexible definition and extension of your application range.

The acoustic waveguide measures precisely and reliably, even the smallest changes are detected

Continuous quality monitoring of beverages and in cleaning processes

Device properties

Nominal diameter: DN 25 (1")

Sensor housing made of stainless steel (3-A, EHEDG)

Accurate and independent of flow profile

Industry-compliant, easy installation via DIN rail and pipe mounting set

3.5" TFT color touch screen or LED indication

4-20 mA, Modbus TCP

Key Benefits

  • High accuracy and repeatability – concentration calculation with latest algorithms
  • Fulfilment of hygienic requirements – easily cleanable full-bore sensor
  • Full transparency – constant monitoring of product quality without sampling
  • Highest process safety – reliable metering due to robust, maintenance-free sensor
  • Customized usage – innovative application concept, expendable for changing measuring tasks
  • Simplified process control – user-friendly operation and clear status visualization
  • Local data backup – integrated data storage for measured values up to 7,5 years

Specifications

Industry

  • Food & Beverage

Product Family

  • Teqwave

Concentration

Product headline

  • Inline device with best-in-class hygienic design – plug and play for food and beverage processes.
  • High accuracy and repeatability – concentration calculation with latest algorithms.
  • Continuous quality monitoring of beverages and in cleaning processes.

Sensor features

  • Fulfilment of hygienic requirements – easily cleanable full-bore sensor. Full transparency – constant monitoring of product quality without sampling. Highest process safety – reliable metering due to robust, maintenance-free sensor.
  • Nominal diameter: DN 25 (1"). Accurate and independent of flow profile. Sensor housing made of stainless steel (3-A, EHEDG).

Transmitter features

  • Customized usage – innovative application concept, expendable for changing measuring tasks. Simplified process control – user-friendly operation and clear status visualization. Local data backup – integrated data storage for measured values up to 7,5 years.
  • Industry-compliant, easy installation via DIN rail. 3.5" TFT color touch screen or LED indication. 4-20 mA, Modbus TCP.

Nominal diameter range

  • DN 25 (1“ DIN and ANSI)

Measured variables

  • Concentration, sound velocity, temperature, acoustic density, dispersion

Max. measurement error

  • Acoustic density: ±0.01g/cm³
  • Temperature: ±0.5K
  • Sound velocity: +-2m/s

Measuring range

  • Concentration According to concentration app data sheet, maximum 0 to 100 %
  • Sound velocity 600 to 2000 m/s
  • Temperature, maximum 0 to +100 °C (32 to +212 °F)
  • Acoustic density 0.7 to 1.5 g/cm³

Design

  • Inline, hygienic

Material

  • Sensor material: Stainless steel 1.4404 (316L)
  • Transmitter housing material: Anodized aluminium and glas, optional 1.4301 and plastic

Process temperature

  • 0 to 120°C (32 to 248 °F)

Process pressure

  • max. 16 bar at 20 °C (232 psi at 68 °F)

Ex certification

  • Non-hazardous area

Ingress protection

  • Sensor: IP67, IP69 optional
  • Transmitter: IP40, optional IP67

Display/Operation

  • LED status indication
  • TFT color touch display

Outputs

  • Modbus TCP, Relay (AC 50V, DC30V 1A), 4-20mA/0 to 10V Analog output

Power supply

  • DC 24V +-20%

Product safety

  • CE, UKCA, RCM

Density/Concentration

Product headline

  • Inline device with best-in-class hygienic design – plug and play for food and beverage processes.
  • High accuracy and repeatability – concentration calculation with latest algorithms.
  • Continuous quality monitoring of beverages and in cleaning processes.

Sensor features

  • Fulfilment of hygienic requirements – easily cleanable full-bore sensor. Full transparency – constant monitoring of product quality without sampling. Highest process safety – reliable metering due to robust, maintenance-free sensor.
  • Nominal diameter: DN 25 (1"). Accurate and independent of flow profile. Sensor housing made of stainless steel (3-A, EHEDG).

Transmitter features

  • Customized usage – innovative application concept, expendable for changing measuring tasks. Simplified process control – user-friendly operation and clear status visualization. Local data backup – integrated data storage for measured values up to 7,5 years.
  • Industry-compliant, easy installation via DIN rail. 3.5" TFT color touch screen or LED indication. 4-20 mA, Modbus TCP.

Nominal diameter range

  • DN 25 (1“ DIN and ANSI)

Wetted materials

  • Stainless steel1.4404 (316L)

Measured variables

  • Concentration, sound velocity, temperature, acoustic density, dispersion

Max. measurement error

  • Acoustic density: ±0.01g/cm³
  • Temperature: ±0.5K
  • Sound velocity: +-2m/s

Measuring range

  • Concentration According to concentration app data sheet, maximum 0 to 100 %
  • Sound velocity 600 to 2000 m/s
  • Temperature maximum 0 to +100 °C (32 to +212 °F)
  • Acoustic Density 0.7 to 1.5 g/cm³

Max. process pressure

  • max. 16 bar at 20 °C (232 psi at 68 °F)

Medium temperature range

  • 0 to 120°C (32 to 248 °F)

Ambient temperature range

  • 0 to 60 °C (32 to 140 °F)

Sensor housing material

  • Stainless steel 1.4404 (316L)

Transmitter housing material

  • Anodized aluminium and glas, optional 1.4301 and plastic

Degree of protection

  • Sensor: IP67, IP69 optional
  • Transmitter: IP40, IP67 optional

Display/Operation

  • LED status indication
  • TFT color touch display

Outputs

  • Modbus TCP, Relay (AC 50V, DC30V 1A), 4-20mA/0 to 10V Analog output

Inputs

  • 2 digital inputs for configuring the display and output during operation.

Power supply

  • DC 24V +-20%

Hazardous area approvals

  • Non-hazardous area

Product safety

  • CE, UKCA, RCM

Material certificates

  • 3.1 acceptance test certificate

Hygienic approvals and certificates

  • EHEDG, 3-A, seals and wetted parts according to EU1935, FDA and FCM China
show more