Electromagnetic flowmeter Promag W 5W3B

Brand: Endress+Hauser

Electromagnetic flowmeter Promag W 5W3B

Brand: Endress+Hauser

Forberg Smith, Endress+Hauser's exclusive USA representative in:
KY MI OH PA  Parts of WI WV 

Extended Extended
Heartbeat Technology Heartbeat Technology

Specs at a Glance

Wetted materials:
Liner: Polyurethane; Hard rubber, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Measuring range:
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Max. process pressure:
PN 40, Class 300, 20K
Medium temperature range:
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Max. measurement error:
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

Field of application

Promag W 300 is the pecialist for demanding water and wastewater applications with a compact, easily accessible transmitter. It was designed for reliable measurements in hazardous areas and under harsh conditions. This flowmeter is dedicated for measurement tasks in industrial or municipal water and wastewater applications.

Key Benefits

  • Reliable measurement – patented full-bore sensor without pressure loss requires no in-/outlet runs and ensures constant accuracy
  • Flexible engineering – sensor is available with fixed or lap-joint process connections
  • Long-term operation – robust and completely welded sensor
  • Full access to process and diagnostic information – Ethernet and numerous, freely combinable I/Os which reduce complexity

Specifications

Product Family

  • Promag

Liquids

Product headline

  • Specialist for demanding water and wastewater applications with a compact, easily accessible transmitter.
  • Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss.
  • Dedicated to the measurement of industrial or municipal water and wastewater .

Sensor features

  • Flexible engineering – sensor with fixed or lap-joint process connections. Long-term operation – robust and completely welded sensor. Improved plant availability – sensor compliant with industry-specific requirements.
  • International drinking water approvals.

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
  • Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

Nominal diameter range

  • DN 25 to 3000(1 to 120")

Wetted materials

  • Liner: Polyurethane; Hard rubber, PTFE
  • Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

Measured variables

  • Volume flow, conductivity, mass flow

Max. measurement error

  • Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
  • Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

Measuring range

  • 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)

Max. process pressure

  • PN 40, Class 300, 20K

Medium temperature range

  • Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
  • Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
  • Liner material PTFE: –20 to +90 °C (–4 to +194 °F)

Ambient temperature range

  • Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
  • Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

Sensor housing material

  • DN 25 to 300 (1 to 12"): AlSi10Mg, coated
  • DN 25 to 2400 (1 to 90"): Carbon steel with protective varnish
  • Sensor connection housing (standard): AlSi10Mg, coated
  • Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L

Transmitter housing material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA WirelessHART
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Double pulse output (active/passive)
  • Relay output

Inputs

  • Status input 4-20 mA input

Digital communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC

Product safety

  • CE, C-tick, EAC marking

Functional safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine approvals and certificates

  • LR approval, DNV approval, ABS approval, BV approval

Pressure approvals and certificates

  • CRN, PED

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • ACS, KTW/W270, NSF 61, WRAS BS 6920

No Videos

show more