Raman probe KR10
Brand: Endress+HauserRaman probe KR10
Brand: Endress+Hauser
Extended
Specs at a Glance
532 nm, 785 nm, 1000 nm
With bIO-Optic or Raman optic system for single use:
785 nm, 1000 nm
With bio multi optic and bio sleeve or Raman flow assembly:
785 nm
Field of application
Designed for product and process development, the Rxn-10 probe is the workhorse of the Raman probe portfolio. It is trusted to deliver high performance Raman measurements across a wide spectral range. It is also compact, lightweight, and flexible, offering multi-purpose convenience for solids and liquids analysis in the laboratory environment. The Rxn-10 probe accepts a variety of interchangeable optics, making it a highly versatile and easily adaptable instrument in your laboratory toolbox.
Chemical: reaction monitoring, blending, catalysis, hydrocarbon speciation, process unit optimization
Polymer: polymerization reaction monitoring, extrusion monitoring, polymer blending
Pharmaceutical: API reaction monitoring, crystallization
Biopharmaceutical: monitoring, optimization, and control of cell culture, fermentation, and downstream applications
Food & Beverage: zonal heterogeneity mapping of meats and fish
Key Benefits
- Multipurpose use for both solids and liquids measurement
- Lightweight and compact
- Integrated laser safety interlock, including “laser on” indication and probe shutter
- Flexible output compatible with a range of sampling options
- Easy switching of non-contact, immersion, and bioprocessing optics to suit a variety of applications
- Wide spectral range, including access to the critical low-wavenumber region
Specifications
Brand
Industry
- Chemical
- Food & Beverage
- Life Science
Product Family
- Raman
Liquids
Laser wavelength
- With non-contact and immersion optic:
- 532 nm, 785 nm, 1000 nm
- With bIO-Optic or Raman optic system for single use:
- 785 nm, 1000 nm
- With bio multi optic and bio sleeve or Raman flow assembly:
- 785 nm
Spectral coverage
- Probe spectral coverage is limited by the coverage of the analyzer being used.
Ambient temperature
- –10 to 70 °C / 14 to 158 °F
Relative humidity
- 20 to 60 %, non-condensing
Maximum laser power into probehead (mW)
- < 499
Sample interface
- Varies based on model
Body and window materials
- Rxn-10 probe body: 6061 aluminum, 316L stainless steel, and 303 stainless steel
Fiber optic cable
- Design, KFOC1 Raman fiber-optic cable:
- Rigid PVC jacketed, proprietary construction
- Design, KFOC1B Raman fiber-optic cable:
- Flexible PVC jacketed, proprietary construction
- Connections: proprietary electro-optic (EO), or FC to EO fiber converter(s) for non-embedded systems
- Temperature:
- -40 to 70 °C / -40 to 158 °F
- Standard length:
- 5000 mm / 196.86 inch
- 25000 mm / 984.26 inch
- Also available in 5000 mm / 196.86 inch increments
- Minimum bend radius:
- 152.4 mm / 6 inch
Length
- Rxn-10 probe (including fiber cable bend radius): 356 mm / 14.02 inch
Diameter
- Rxn-10 probe:
- 19 mm / 0.75 inch
Working distance
- Based on the sampling optic selected
Solids
Laser wavelength
- 532 nm, 785 nm, 1000 nm
Spectral coverage
- Probe spectral coverage is limited by the coverage of the analyzer being used.
Ambient temperature
- Probe:
- –10 to 70 °C / 14 to 158 °F
Relative humidity
- 20 to 60 %, non-condensing
Maximum laser power into probehead (mW)
- < 499
Sample interface
- Varies based on model
Body and window materials
- Rxn-10 probe body: 6061 aluminum, 316L stainless steel, and 303 stainless steel
Fiber optic cable
- Design, KFOC1 Raman fiber-optic cable:
- Rigid PVC jacketed, proprietary construction
- Design, KFOC1B Raman fiber-optic cable:
- Flexible PVC jacketed, proprietary construction
- Connections: proprietary electro-optic (EO), or FC to EO fiber converter(s) for non-embedded systems
- Temperature:
- -40 to 70 °C / -40 to 158 °F
- Standard length:
- 5000 mm / 196.86 inch
- 25000 mm / 984.26 inch
- Also available in 5000 mm / 196.86 inch increments
- Minimum bend radius:
- 152.4 mm / 6 inch
Length
- Rxn-10 probe (including fiber cable bend radius):
- 356 mm / 14.02 inch
Diameter
- Rxn-10 probe:
- 19 mm / 0.75 inch
Working distance
- Based on the sampling optic selected