Proline Prosonic Flow E 100 Ultrasonic Flowmeter

Brand: Endress+Hauser

Proline Prosonic Flow E 100 Ultrasonic Flowmeter

Brand: Endress+Hauser

Local Support: Authorized Distributor Serving Michigan, West Virginia and parts of Wisconsin, Ohio, Pennsylvania and Kentucky.

Extended Extended

Measuring of demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. Prosonic Flow E 100 provides economical and accurate bidirectional flow measurement across all industries. with its integrated temperature measurement, Prosonic Flow E 100 proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

  • The measuring principle is independent of pressure, density, temperature and conductivity
  • Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines

Device properties:

  • Accuracy up to ±0.5 % (flow) or acc. to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temp.)
  • Process temperatures up to 150 °C (302 °F)
  • Entire meter housing made of stainless steel
  • 4-20 mA HART, pulse/frequency output
  • Local display for reading and monitoring available
  • Robust transmitter housing
Features
  • Long-term stability – reliable, robust sensor
  • Reducing further measuring point – multivariable device
  • Dependable flow measurement – high turndown (200:1)
  • Time-saving local operation without additional software and hardware – integrated web server
  • Extended calibration intervals – integrated device verification due to Heartbeat Technology
  • Easy commissioning – brief parameter explanations

Specifications

Product Family

  • Prosonic

Measuring Principle

  • Ultrasonic Flow

Product Headline

  • Economical Ultrasonic flowmeter with integrated temperature measurement
  • Bidirectional measuring of demineralized water applications for Utilities, e.g. boiler condensate return lines

Sensor Features

  • Long-term stability – reliable, robust sensor. Reducing further measuring point – multivariable device. Dependable flow measurement – high turndown (200:1)
  • Measurement accuracy up to ±0.5 % (flow) or according to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temperature). Process temperatures up to 150 °C (302 °F). Entire meter housing made of stainless steel

Transmitter Features

  • Time-saving local operation without additional software and hardware – integrated web server. Extended calibration intervals – integrated device verification due to Heartbeat Technology. Easy commissioning – brief parameter explanations
  • 4-20 mA HART, pulse/frequency output. Local display for reading and monitoring available. Robust transmitter housing

Nominal Diameter Range

  • DN 50 to 150 (2"to 6")

Wetted Materials

  • Measuring tube: 1.4301 (F304)
  • Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105

Measured Variables

  • Volume flow, calculated mass flow, flow velocity, sound velocity, temperature

Max. Measurement Error

  • ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
  • ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)

Measuring Range

  • 0.025 to 5 m/s (0.02 to 16.4 ft/s)
  • 0 to 6360 dm3/min (0 to 1680 gal/min)

Max. Process Pressure

  • PN 25 / ASME Cl. 150

Medium Temperature Range

  • 0 to 150° (17.8 to 302 °F)

Ambient Temperature

  • -20 to 60 °C (-4 to 140 °F)

Sensor Housing Material

  • Stainless steel

Transmitter Housing Material

  • Compact:
  • AlSi10Mg, coated
  • Stainless steel, 1.4301

Degree of Protection

  • Standard: IP66/67, Type 4X enclosure
  • With opened housing: IP20, Type 1 enclosure

Display/Operation

  • 4‐line backlit display available (no local operation)
  • Configuration via web browser and operating tools possible

Outputs

  • 4‐20 mA HART (active)
  • Pulse/frequency/switch output (passive)

Inputs

  • None

Power Supply

  • DC 19.2 to 28.8 V

Hazardous Area Approvals

  • None

Product Safety

  • CE, C-Tick, EAC marking

Metrological Approvals and Certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
  • Calibration according to EN 1434 Class 2

Pressure Approvals and Certificates

  • PED

Material Certificates

  • 3.1 material
show more