Vortex flowmeter Prowirl D 7D2C
Brand: Endress+HauserVortex flowmeter Prowirl D 7D2C
Brand: Endress+Hauser
Lean
Heartbeat Technology Specs at a Glance
Medium temperature range:
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
Measuring range:
Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Wetted materials:
Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4435 (316/316L)
DSC sensor: 1.4435 (316/316L)
Max. process pressure:
PN 40, Class 300, 20K
Max. measurement error:
Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 %
Field of application
Prowirl D 200 can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. The genuine loop-powered technology allows for seamless integration into existing infrastructures. Prowirl D offers highest operational safety in hazardous areas and Heartbeat Technology enables process safety at all times.
Key Benefits
- Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
- Integrated temperature measurement for mass/energy flow of saturated steam
- Easy alignment of the sensor thanks to included centering rings
- High availability – proven robustness, resistance to vibrations, temperature shocks and water hammer
- Long-term stability – robust drift-free capacitive sensor
Specifications
Brand
Product Family
- Prowirl
Gas
Product headline
- Cost-effective wafer flowmeter, available as compact or remote version.
- Integrated temperature measurement for mass/energy flow of saturated steam.
- For all basic applications and for 1-to-1 replacement of orifice plates.
Sensor features
- Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor.
- Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.
Transmitter features
- Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
- Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range
- DN 15 to 150 (½ to 6")
Wetted materials
- Measuring tube: 1.4408 (CF3M)
- DSC sensor: 1.4435 (316/316L)
Measured variables
- Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. measurement error
- Volume flow (liquid): ±0.75 %
- Volume flow (steam, gas): ±1.00 %
- Mass flow (liquid): ±0.85%
- Mass flow (steam, gas): ±1.7 %
Measuring range
- Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
- depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
- Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
- depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. process pressure
- PN 40, Class 300, 20K
Medium temperature range
- Standard: –40 to +260 °C (–40 to +500 °F)
- High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
- High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
Ambient temperature range
- Compact version (standard): –40 to +80 °C (–40 to +176 °F)
- Compact version (option): –50 to +80 °C (–58 to +176 °F)
- Remote version (standard): –40 to +85 °C (–40 to +185 °F)
- Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing material
- Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing material
- AlSi10Mg, coated; 1.4404 (316L)
Degree of protection
- Compact version: IP66/67, type 4X enclosure
- Sensor remote version: IP66/67, type 4X enclosure
- Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation
- 4‐line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
- Remote display available
Outputs
- 4‐20 mA HART (passive)
- 4‐20 mA (passive)
- Pulse/frequency/switch output (passive)
Inputs
- Current input 4‐20 mA (passive)
Digital communication
- HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply
- DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
- DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
- DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
- DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvals
- ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
Product safety
- CE, C-TICK, EAC
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates
- ABS, LR, BV, DNV
Pressure approvals and certificates
- PED, CRN
Material certificates
- 3.1 material
- NACE MR0175/MR0103, PMI (on request)
Liquids
Product headline
- Cost-effective wafer flowmeter, available as compact or remote version.
- Integrated temperature measurement for mass/energy flow of saturated steam.
- For all basic applications and for 1-to-1 replacement of orifice plates.
Sensor features
- Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor.
- Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.
Transmitter features
- Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
- Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range
- DN 15 to 150 (½ to 6")
Wetted materials
- Measuring tube: 1.4408 (CF3M)
- DSC sensor: 1.4435 (316/316L)
Measured variables
- Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. measurement error
- Volume flow (liquid): ±0.75 %
- Volume flow (steam, gas): ±1.00 %
- Mass flow (liquid): ±0.85%
- Mass flow (steam, gas): ±1.7 %
Measuring range
- Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
- depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
- Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
- depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. process pressure
- PN 40, Class 300, 20K
Medium temperature range
- Standard: –40 to +260 °C (–40 to +500 °F)
- High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
- High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
Ambient temperature range
- Compact version (standard): –40 to +80 °C (–40 to +176 °F)
- Compact version (option): –50 to +80 °C (–58 to +176 °F)
- Remote version (standard): –40 to +85 °C (–40 to +185 °F)
- Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing material
- Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing material
- AlSi10Mg, coated; 1.4404 (316L)
Degree of protection
- Compact version: IP66/67, type 4X enclosure
- Sensor remote version: IP66/67, type 4X enclosure
- Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation
- 4‐line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
- Remote display available
Outputs
- 4‐20 mA HART (passive)
- 4‐20 mA (passive)
- Pulse/frequency/switch output (passive)
Inputs
- Current input 4‐20 mA (passive)
Digital communication
- HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply
- DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
- DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
- DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
- DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvals
- ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
Product safety
- CE, C-TICK, EAC
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates
- ABS, LR, BV, DNV
Pressure approvals and certificates
- PED, CRN
Material certificates
- 3.1 material
- NACE MR0175/MR0103, PMI (on request)
Steam
Product headline
- Cost-effective wafer flowmeter, available as compact or remote version.
- Integrated temperature measurement for mass/energy flow of saturated steam.
- For all basic applications and for 1-to-1 replacement of orifice plates.
Sensor features
- Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor.
- Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.
Transmitter features
- Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
- Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range
- DN 15 to 150 (½ to 6")
Wetted materials
- Measuring tube: 1.4408 (CF3M)
- DSC sensor: 1.4435 (316/316L)
Measured variables
- Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. measurement error
- Volume flow (liquid): ±0.75 %
- Volume flow (steam, gas): ±1.00 %
- Mass flow (liquid): ±0.85%
- Mass flow (steam, gas): ±1.7 %
Measuring range
- Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
- depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
- Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
- depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. process pressure
- PN 40, Class 300, 20K
Medium temperature range
- Standard: –40 to +260 °C (–40 to +500 °F)
- High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
- High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
Ambient temperature range
- Compact version (standard): –40 to +80 °C (–40 to +176 °F)
- Compact version (option): –50 to +80 °C (–58 to +176 °F)
- Remote version (standard): –40 to +85 °C (–40 to +185 °F)
- Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing material
- Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing material
- AlSi10Mg, coated; 1.4404 (316L)
Degree of protection
- Compact version: IP66/67, type 4X enclosure
- Sensor remote version: IP66/67, type 4X enclosure
- Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation
- 4‐line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
- Remote display available
Outputs
- 4‐20 mA HART (passive)
- 4‐20 mA (passive)
- Pulse/frequency/switch output (passive)
Inputs
- Current input 4‐20 mA (passive)
Digital communication
- HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply
- DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
- DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
- DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
- DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvals
- ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
Product safety
- CE, C-TICK, EAC
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates
- ABS, LR, BV, DNV
Pressure approvals and certificates
- PED, CRN
Material certificates
- 3.1 material
- NACE MR0175/MR0103, PMI (on request)