Raman probe KR30

Brand: Endress+Hauser

Raman probe KR30

Brand: Endress+Hauser

Forberg Smith, Endress+Hauser's exclusive USA representative in:
KY MI OH PA  Parts of WI WV 

Extended Extended

Specs at a Glance

Laser wavelength:
532 nm
Hazardous area certifications:
ATEX, CSA, IECEx, UKCA, JPEx

Field of application

The Raman Rxn-30 probe has cross-industry appeal for its robust gas-phase headspace monitoring, in situ measurements, and material compatibility. Certified for use in hazardous area environments, the Raman Rxn-30 probe can be inserted directly into processes with temperatures up to 150 degrees Celsius and pressures up to 68.9 barg (1,000 psig). It is available with a variety of mounting options for maximum installation and sampling flexibility.

Chemical: ammonia, methanol, HyCO, reaction monitoring, blending, catalysis

Polymer: polymerization reaction monitoring

Gas-phase streams in refining: hydrogen production and recycle fuel blending, fuel characterization

Power & Energy: IGCC power plants, gas turbines

Pharmaceutical: API reaction monitoring, drying

Food & Beverage: fermentations, offgas, volatiles

Key Benefits

  • Reliable, quantitative gas-phase measurements
  • In situ measurement/no transfer lines or fast loops required
  • Can be directly inserted into processes with temperatures up to 150 °C and 68.9 barg (1,000 psig)
  • Industry standard installation options
  • Direct insertion, side insertion, or sample loop
  • Suitable for hazardous area/classified environments

Specifications

Industry

  • Chemical
  • Food & Beverage
  • Power & Energy
  • Oil & Gas
  • Life Science

Product Family

  • Raman

Gases

Laser wavelength

  • 532 nm

Spectral coverage

  • Probe spectral coverage is limited by the coverage of the analyzer being used.

Ambient temperature

  • Nonexplosive environments:
  • -20 to 150 °C / -4 to 302 °F
  • Explosive environments:
  • T4: –20 to 70 °C / –4 to 158 °F
  • T6: –20 to 65 °C / –4 to 149 °F
  • Limited to normal ambient temperature
  • IEC 60079-0 for Korea

Relative humidity

  • 0 to 95%, non-condensing

Maximum laser power into probehead (mW)

  • < 499

Sample interface

  • Probe operating temperature:
  • -20 to 150 °C / -4 to 302 °F
  • Temperature ramp:
  • ≤ 6 °C/min
  • ≤ 10.8 °F/min

Pressure

  • Max pressure: (at sample)
  • 68.9 barg / 1000 psig

Wetted materials

  • 316/316L stainless steel
  • PTFE
  • Sapphire
  • Fused silica glass

Fiber optic cable

  • Cable sold separately

Gas stream filtration

  • 20 μm or better
  • Integrated 20 μm particle filter standard with Rxn-30 probes

Hazardous area certifications

  • ATEX, CSA, IECEx, UKCA, JPEx
show more