Coriolis flowmeter Promass A 8A1B

Brand: Endress+Hauser

Coriolis flowmeter Promass A 8A1B

Brand: Endress+Hauser

Forberg Smith, Endress+Hauser's exclusive USA representative in:
KY MI OH PA  Parts of WI WV 

Extended Extended
Heartbeat Technology Heartbeat Technology

Specs at a Glance

Medium temperature range:
–50 to +205 °C (–58 to +401 °F)
Max. process pressure:
PN 40, Class 300, 20K, 400 bar (5800 psi)
Max. measurement error:
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range:
0 to 450 kg/h (0 to 16.5 lb/min)
Wetted materials:
Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)

Field of application

Coriolis flowmeter
Application: Measuring accurately
smallest quantities of liquids and
gases for continuous process control.
Self-drainable single-tube system.
Rated 2nd containment: 25 bar (362 psi).
Transmitter: Robust, ultra-compact.

Specifications

Industry

  • Food & Beverage
  • Life Science

Product Family

  • Promass

Density/Concentration

Product headline

  • The single-tube flowmeter for smallest flow quantities with an ultra-compact transmitter.
  • Measuring accurately smallest quantities of liquids and gases for continuous process control.

Sensor features

  • Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).

Transmitter features

  • Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
  • Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

Nominal diameter range

  • DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")

Wetted materials

  • Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
  • Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

  • Mass flow (liquid): ±0.1 %
  • Volume flow (liquid): ±0.1 %
  • Mass flow (gas): ±0.5 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 450 kg/h (0 to 16.5 lb/min)

Max. process pressure

  • PN 40, Class 300, 20K, 400 bar (5800 psi)

Medium temperature range

  • –50 to +205 °C (–58 to +401 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301 (304), corrosion resistant

Transmitter housing material

  • Compact: AlSi10Mg, coated
  • Compact/ultra-compact: 1.4301 (304)

Degree of protection

  • Standard: IP66/67, type 4X enclosure
  • Option: IP69

Display/Operation

  • 4‐line backlit display available (no local operation)
  • Configuration via web browser and operating tools possible

Outputs

  • 4‐20 mA HART (active)
  • Pulse/frequency/switch output (passive)

Inputs

  • None

Digital communication

  • HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply

  • DC 20 to 30 V

Hazardous area approvals

  • ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

Product safety

  • CE, C-Tick, EAC marking

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure approvals and certificates

  • CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • 3-A, EHEDG, cGMP

Gas

Product headline

  • The single-tube flowmeter for smallest flow quantities with an ultra-compact transmitter.
  • Measuring accurately smallest quantities of liquids and gases for continuous process control.

Sensor features

  • Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).

Transmitter features

  • Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
  • Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

Nominal diameter range

  • DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")

Wetted materials

  • Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
  • Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

  • Mass flow (liquid): ±0.1 %
  • Volume flow (liquid): ±0.1 %
  • Mass flow (gas): ±0.5 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 450 kg/h (0 to 16.5 lb/min)

Max. process pressure

  • PN 40, Class 300, 20K, 400 bar (5800 psi)

Medium temperature range

  • –50 to +205 °C (–58 to +401 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301 (304), corrosion resistant

Transmitter housing material

  • Compact: AlSi10Mg, coated
  • Compact/ultra‐compact: 1.4301 (304)

Degree of protection

  • Standard: IP66/67, type 4X enclosure
  • Option: IP69

Display/Operation

  • 4‐line backlit display available (no local operation)
  • Configuration via web browser and operating tools possible

Outputs

  • 4‐20 mA HART (active)
  • Pulse/frequency/switch output (passive)

Inputs

  • None

Digital communication

  • HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply

  • DC 20 to 30 V

Hazardous area approvals

  • ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

Other approvals and certificates

    Product safety

    • CE, C-Tick, EAC marking

    Metrological approvals and certificates

    • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

    Pressure approvals and certificates

    • CRN

    Material certificates

    • 3.1 material

    Hygienic approvals and certificates

    • 3-A, EHEDG, cGMP

    Liquids

    Product headline

    • The single-tube flowmeter for smallest flow quantities with an ultra-compact transmitter.
    • Measuring accurately smallest quantities of liquids and gases for continuous process control.

    Sensor features

    • Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    • Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).

    Transmitter features

    • Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
    • Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

    Nominal diameter range

    • DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")

    Wetted materials

    • Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
    • Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)

    Measured variables

    • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

    Max. measurement error

    • Mass flow (liquid): ±0.1 %
    • Volume flow (liquid): ±0.1 %
    • Mass flow (gas): ±0.5 %
    • Density (liquid): ±0.0005 g/cm³

    Measuring range

    • 0 to 450 kg/h (0 to 16.5 lb/min)

    Max. process pressure

    • PN 40, Class 300, 20K, 400 bar (5800 psi)

    Medium temperature range

    • –50 to +205 °C (–58 to +401 °F)

    Ambient temperature range

    • Standard: –40 to +60 °C (–40 to +140 °F)
    • Option: –50 to +60 °C (–58 to +140 °F)

    Sensor housing material

    • 1.4301 (304), corrosion resistant

    Transmitter housing material

    • Compact: AlSi10Mg, coated
    • Compact/ultra-compact: 1.4301 (304)

    Degree of protection

    • Standard: IP66/67, type 4X enclosure
    • Option: IP69

    Display/Operation

    • 4‐line backlit display available (no local operation)
    • Configuration via web browser and operating tools possible

    Outputs

    • 4‐20 mA HART (active)
    • Pulse/frequency/switch output (passive)

    Inputs

    • None

    Digital communication

    • HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

    Power supply

    • DC 20 to 30 V

    Hazardous area approvals

    • ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

    Product safety

    • CE, C-Tick, EAC marking

    Metrological approvals and certificates

    • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
    • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

    Pressure approvals and certificates

    • CRN

    Material certificates

    • 3.1 material

    Hygienic approvals and certificates

    • 3-A, EHEDG, cGMP
    show more