Specs at a Glance

Wetted materials:
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Max. process pressure:
PN 40, Class 150, 20K
Medium temperature range:
–50 to +150 °C (–58 to +302 °F)
Max. measurement error:
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
Measuring range:
0 to 70 000 kg/h (0 to 2570 lb/min)

Field of application

Promass S is at the forefront in hygienic design – Endress+Hauser’s industry-optimized measurement solution meets all the hygienic requirements for installation in the Food and Beverage industry. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Designed for applications where space is a premium, Promass S 100 will be the preferred choice for system integrators, skid builders and equipment manufacturer.

Measuring principle operates independently of physical fluid properties such as viscosity or density

Dedicated for applications requiring optimal cleanability under hygienic conditions.

Device properties

Large range of hygienic process connections

3-A and EHEDG conform

Fast recovery from CIP/SIP

Robust, ultra-compact transmitter housing

High ingress protection: IP69K

Local display available

Key Benefits

  • Reduced installation costs – fully self-drainable tube design enables compact horizontal mounting
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in/outlet run needs
  • Space-saving transmitter – full functionality on smallest footprint
  • Time-saving local operation without additional software and hardware – integrated web server
  • Integrated verification – Heartbeat Technology

Specifications

Industry

  • Food & Beverage
  • Life Science

Product Family

  • Promass

Density/Concentration

Product headline

  • Easy-to-clean flowmeter with self-drainable single-tube system and an ultra-compact transmitter.
  • Dedicated to applications requiring optimal cleanability under hygienic conditions.

Sensor features

  • Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.

Transmitter features

  • Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
  • Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

Nominal diameter range

  • DN 8 to 50 (⅜ to 2")

Wetted materials

  • Measuring tube: 1.4435 (316L)
  • Connection: 1.4435 (316L); 1.4404 (316/316L)

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

  • Mass flow (liquid): ±0.10 %
  • Volume flow (liquid): ±0.10 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 70 000 kg/h (0 to 2570 lb/min)

Max. process pressure

  • PN 40, Class 150, 20K

Medium temperature range

  • –50 to +150 °C (–58 to +302 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301 (304), corrosion resistant

Transmitter housing material

  • Compact: AlSi10Mg, coated
  • Compact/ultra‐compact: 1.4301 (304)

Degree of protection

  • Standard: IP66/67, type 4X enclosure
  • Option: IP69

Display/Operation

  • 4‐line backlit display available (no local operation)
  • Configuration via web browser and operating tools possible

Outputs

  • 4‐20 mA HART (active)
  • Pulse/frequency/switch output (passive)

Inputs

  • None

Digital communication

  • HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply

  • DC 20 to 30 V

Hazardous area approvals

  • ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

Product safety

  • CE, C-Tick, EAC marking

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure approvals and certificates

  • PED, CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • 3‐A, EHEDG, cGMP

Gas

Hygienic approvals and certificates

  • cGMP

Liquids

Product headline

  • Easy-to-clean flowmeter with self-drainable single-tube system and an ultra-compact transmitter.
  • Dedicated to applications requiring optimal cleanability under hygienic conditions.

Sensor features

  • Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP.

Transmitter features

  • Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
  • Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.

Nominal diameter range

  • DN 8 to 50 (⅜ to 2")

Wetted materials

  • Measuring tube: 1.4435 (316L)
  • Connection: 1.4435 (316L); 1.4404 (316/316L)

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

  • Mass flow (liquid): ±0.10 %
  • Volume flow (liquid): ±0.10 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 70 000 kg/h (0 to 2570 lb/min)

Max. process pressure

  • PN 40, Class 150, 20K

Medium temperature range

  • –50 to +150 °C (–58 to +302 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301 (304), corrosion resistant

Transmitter housing material

  • Compact: AlSi10Mg, coated
  • Compact/ultra‐compact: 1.4301 (304)

Degree of protection

  • Standard: IP66/67, type 4X enclosure
  • Option: IP69

Display/Operation

  • 4‐line backlit display available (no local operation)
  • Configuration via web browser and operating tools possible

Outputs

  • 4‐20 mA HART (active)
  • Pulse/frequency/switch output (passive)

Inputs

  • None

Digital communication

  • HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET

Power supply

  • DC 20 to 30 V

Hazardous area approvals

  • ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

Product safety

  • CE, C-Tick, EAC marking

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure approvals and certificates

  • PED, CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • 3‐A, EHEDG, cGMP
show more