Specs at a Glance

Medium temperature range:
–50 to +150 °C (–58 to +302 °F)
Wetted materials:
Measuring tube: Titanium grade 9
Connection: Titanium grade 2
Max. process pressure:
PN 100, Class 600, 63K
Measuring range:
0 to 180 000 kg/h (0 to 6600 lb/min)
Max. measurement error:
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³

Field of application

The straight single-tube design of Promass I provides in-line viscosity measurement in addition to mass flow, density and temperature measurement. With its compact transmitter Promass I 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.

Measuring principle operates independently of physical fluid properties such as viscosity or density

Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment

Device properties

Straight, easy-to-clean single-tube system

TMB technology

Measuring tube made of Titanium

Compact dual-compartment housing with up to 3 I/Os

Backlit display with touch control and WLAN access

Remote display available

Key Benefits

  • Energy-saving – full bore design enables minimal pressure loss
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in-/outlet run needs
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology

Specifications

Industry

  • Chemical
  • Food & Beverage
  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Life Science

Product Family

  • Promass

Density

Product Headline

  • Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
  • .
  • Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

Sensor features

  • Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
  • Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

Density/Concentration

Product headline

  • Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
  • .
  • Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

Sensor features

  • Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
  • Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

Nominal diameter range

  • DN 8 to 80 (⅜ to 3")

Wetted materials

  • Measuring tube: Titanium grade 9
  • Connection: Titanium grade 2

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity

Max. measurement error

  • Mass flow (liquid): ±0.10 %
  • Volume flow (liquid): ±0.10 %
  • Mass flow (gas): ±0.50 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 180 000 kg/h (0 to 6600 lb/min)

Max. process pressure

  • PN 100, Class 600, 63K

Medium temperature range

  • –50 to +150 °C (–58 to +302 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301/1.4307 (304L), corrosion resistant

Transmitter housing material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

Degree of protection

  • IP66/67, type 4X enclosure
  • IP69

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product safety

  • CE, C-tick, EAC marking

Functional safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure approvals and certificates

  • PED, CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • 3-A, EHEDG, cGMP

Gas

Product headline

  • Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
  • .
  • Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

Sensor features

  • Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
  • Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

Nominal diameter range

  • DN 8 to 80 (⅜ to 3")

Wetted materials

  • Measuring tube: Titanium grade 9
  • Connection: Titanium grade 2

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

  • Mass flow (liquid): ±0.10 %
  • Volume flow (liquid): ±0.10 %
  • Mass flow (gas): ±0.50 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 180 000 kg/h (0 to 6615 lb/min)

Max. process pressure

  • PN 100, Class 600, 63K

Medium temperature range

  • –50 to +150 °C (–58 to +302 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301 (304), corrosion resistant

Transmitter housing material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

Degree of protection

  • Standard: IP66/67, Type 4X enclosure
  • Option: IP69

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product safety

  • CE, C-tick, EAC marking

Functional safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure approvals and certificates

  • PED, CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • 3-A, EHEDG, cGMP

Liquids

Product headline

  • Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
  • .
  • Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

Sensor features

  • Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
  • Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

Nominal diameter range

  • DN 8 to 80 (⅜ to 3")

Wetted materials

  • Measuring tube: Titanium grade 9
  • Connection: Titanium grade 2

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity

Max. measurement error

  • Mass flow (liquid): ±0.10 %
  • Volume flow (liquid): ±0.10 %
  • Mass flow (gas): ±0.50 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 180 000 kg/h (0 to 6600 lb/min)

Max. process pressure

  • PN 100, Class 600, 63K

Medium temperature range

  • –50 to +150 °C (–58 to +302 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301/1.4307 (304L), corrosion resistant

Transmitter housing material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

Degree of protection

  • IP66/67, type 4X enclosure
  • IP69

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Relay output

Inputs

  • Status input
  • 4-20 mA input

Digital communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product safety

  • CE, C-tick, EAC marking

Functional safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure approvals and certificates

  • PED, CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • 3-A, EHEDG, cGMP

Viscosity

Product headline

  • Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter.
  • .
  • Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.

Sensor features

  • Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
  • Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
  • Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.

Nominal diameter range

  • DN 8 to 80 (⅜ to 3")

Wetted materials

  • Measuring tube: Titanium grade 9
  • Connection: Titanium grade 2

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity

Max. measurement error

  • Mass flow (liquid): ±0.10 %
  • Volume flow (liquid): ±0.10 %
  • Mass flow (gas): ±0.50 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 180 000 kg/h (0 to 6600 lb/min)

Max. process pressure

  • PN 100, Class 600, 63K

Medium temperature range

  • –50 to +150 °C (–58 to +302 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material

  • 1.4301/1.4307 (304L), corrosion resistant

Transmitter housing material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

Degree of protection

  • " IP66/67, type 4X enclosure
  • IP69"

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible
  • Remote display available

Outputs

  • 3 outputs:
  • 4-20 mA HART (active/passive)
  • 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Relay output

Inputs

  • Status input 4-20 mA input

Digital communication

  • HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC

Product safety

  • CE, C-tick, EAC marking

Functional safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
  • Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Pressure approvals and certificates

  • PED, CRN

Material certificates

  • 3.1 material

Hygienic approvals and certificates

  • 3-A, EHEDG, cGMP
show more