Thermal Mass Flowmeter t-mass 6BAB
Brand: Endress+HauserThermal Mass Flowmeter t-mass 6BAB
Brand: Endress+Hauser
Lean Specs at a Glance
Medium temperature range:
–40 to +100 °C (–40 to +212 °F)
Measuring range:
20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
Wetted materials:
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G
Max. process pressure:
20 bar g (290 psi g)
Max. measurement error:
3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")
Field of application
Proline t-mass B 150 is a thermal mass flowmeter suitable for large pipelines or rectangular ventilation ducts. It is designed for the measurement of utility gases, in particular compressed air. It offers 4-wire technology which is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred to another device via the display.
Key Benefits
- Suitable for air, nitrogen, carbon dioxide and argon in circulare piping or rectangular ducts
- Optimal process monitoring – easy measurement even at low pressures and flow velocities
- Easy installation, negligible pressure loss and maintenance-free
- Fast and efficient commissioning thanks to guided operating menus
- High plant availability due to self-diagnostics and error monitoring
Specifications
Brand
Industry
- Water, Wastewater & Waste
- Power & Energy
- Mining, Minerals & Metals
Product Family
- T-mass
Gas
Product headline
- The flowmeter for cost-effective measurement and easy monitoring of utility gases.
- Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.
Sensor features
- Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement.
- Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption. Easy installation.
Transmitter features
- Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing.
- Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter.
Nominal diameter range
- DN 80 to 1500 (3 to 60")
Wetted materials
- Transducer: 1.4404 (316L)
- Insertion tube: 1.4404 (316L); 1.4435 (316L)
- Connection:
- Compression fitting: 1.4404 (316L)
- Sealing ring: EPDM; HNBR; 1.4401 (316)
- Clamping ring: PEEK 450G
Measured variables
- Mass flow, temperature, corrected volume flow, FAD volume flow
Max. measurement error
- 3 % o.r.
- 4 % o.r.
- 5 % o.f.s.
- (depending on chosen option of ordering feature "Calibration flow")
Measuring range
- 20 to 720 000 kg/h (45 to 1 587 600 lb/h)
- 20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
- (for air, depending on chosen option of ordering feature "Calibration flow")
Max. process pressure
- 20 bar g (290 psi g)
Medium temperature range
- –40 to +100 °C (–40 to +212 °F)
Ambient temperature range
- –40 to +60 °C (–40 to +140 °F)
Transmitter housing material
- AlSi10Mg, coated
Degree of protection
- IP66/67, type 4X enclosure
Display/Operation
- 4‐line display with push Buttons
- Configuration via local display and operating tools possible
Outputs
- 4‐20 mA HART (active)
- Pulse/frequency/switch output (passive)
Inputs
- Status input
Digital communication
- HART
Power supply
- DC 18 to 30 V
Hazardous area approvals
- ATEX, IECEx, cCSAus
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates
- CRN