Vortex flowmeter Prowirl F 7F2C
Brand: Endress+HauserVortex flowmeter Prowirl F 7F2C
Brand: Endress+Hauser
Extended
Heartbeat Technology Specs at a Glance
Max. measurement error:
Volume flow (liquid): ±0.75 %
Volume flow (optional): ±0.65 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85%
Volume flow (optional): ±0.65 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85%
Max. process pressure:
PN 100, Class 600, 20K
Measuring range:
Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Medium temperature range:
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
Wetted materials:
Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
Field of application
The Prowirl F 7F2C** is a versatile flowmeter, offering best-in-class accuracy and the ability to detect wet steam conditions. This device is suitable for a broad range of applications, with a particular optimization for steam applications. It ensures precise measurements, making it an ideal choice for diverse industrial needs.
Specifications
Brand
Product Family
- Prowirl
Gas
Product headline
- Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.
- Easy energy management – integrated temperature and pressure measurement for steam and gases.
- Suitable for a wide range of applications; optimized for steam applications.
Sensor features
- Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor.
- Wet steam capabilities for DN 25 to 300 (1 to 12"). Flexible positioning of pressure cell. Industrial siphon design for pressure measurement.
Transmitter features
- Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
- Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range
- DN 15 to 300 (½ to 12")
Wetted materials
- Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
Measured variables
- Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. measurement error
- Volume flow (liquid): ±0.75 %
- Volume flow (optional): ±0.65 %
- Volume flow (steam, gas): ±1.00 %
- Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
- Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
- Mass flow (liquid): ±0.85%
Measuring range
- Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min)
- depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
- Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min)
- depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. process pressure
- PN 100, Class 600, 20K
Medium temperature range
- Standard: –40 to +260 °C (–40 to +500 °F)
- High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
Ambient temperature range
- Compact version (standard): –40 to +80 °C (–40 to +176 °F)
- Compact version (option): –50 to +80 °C (–58 to +176 °F)
- Remote version (standard): –40 to +85 °C (–40 to +185 °F)
- Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing material
- Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing material
- AlSi10Mg, coated; 1.4404 (316L)
Degree of protection
- Compact version: IP66/67, type 4X enclosure
- Sensor remote version: IP66/67, type 4X enclosure
- Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation
- 4‐line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
- Remote display available
Outputs
- 4‐20 mA HART (passive)
- 4‐20 mA (passive)
- Pulse/frequency/switch output (passive)
Inputs
- Current Input 4‐20 mA (passive)
Digital communication
- HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply
- DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
- DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
- DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
- DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvals
- ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
Product safety
- CE, C-TICK, EAC
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates
- ABS, LR, BV, DNV
Pressure approvals and certificates
- PED, CRN, AD 2000
Material certificates
- 3.1 material
- NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)
Liquids
Product headline
- Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.
- Easy energy management – integrated temperature and pressure measurement for steam and gases.
- Suitable for a wide range of applications; optimized for steam applications.
Sensor features
- Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor.
- Wet steam capabilities for DN 25 to 300 (1 to 12"). Flexible positioning of pressure cell. Industrial siphon design for pressure measurement.
Transmitter features
- Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
- Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range
- DN 15 to 300 (½ to 12")
Wetted materials
- Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
- DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
- Process connection: 1.4404/F316/F316L); 2.4602
Measured variables
- Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. measurement error
- Volume flow (liquid): ±0.75 %
- Volume flow (optional): ±0.65 %
- Volume flow (steam, gas): ±1.00 %
- Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
- Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
- Mass flow (liquid): ±0.85%
Measuring range
- Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min)
- depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
- Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min)
- depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. process pressure
- PN 100, Class 600, 20K
Medium temperature range
- Standard: –40 to +260 °C (–40 to +500 °F)
- High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
Ambient temperature range
- Compact version (standard): –40 to +80 °C (–40 to +176 °F)
- Compact version (option): –50 to +80 °C (–58 to +176 °F)
- Remote version (standard): –40 to +85 °C (–40 to +185 °F)
- Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing material
- Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing material
- AlSi10Mg, coated; 1.4404 (316L)
Degree of protection
- Compact version: IP66/67, type 4X enclosure
- Sensor remote version: IP66/67, type 4X enclosure
- Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation
- 4‐line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
- Remote display available
Outputs
- 4‐20 mA HART (passive)
- 4‐20 mA (passive)
- Pulse/frequency/switch output (passive)
Inputs
- Current Input 4‐20 mA (passive)
Digital communication
- HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply
- DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
- DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
- DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
- DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvals
- ATEX, IECEx, cCSAus, JPN, EAC
Product safety
- CE, C-TICK, EAC, UK Ex
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates
- ABS, LR, BV, DNV
Pressure approvals and certificates
- PED, CRN, AD 2000
Material certificates
- 3.1 material
- NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)
Steam
Product headline
- Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.
- Easy energy management – integrated temperature and pressure measurement for steam and gases.
- Suitable for a wide range of applications; optimized for steam applications.
Sensor features
- Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor.
- Wet steam capabilities for DN 25 to 300 (1 to 12"). Flexible positioning of pressure cell. Industrial siphon design for pressure measurement.
Transmitter features
- Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
- Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range
- DN 15 to 300 (½ to 12")
Wetted materials
- Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
- DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
- Process connection: 1.4404/F316/F316L); 2.4602
Measured variables
- Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. measurement error
- Volume flow (liquid): ±0.75 %
- Volume flow (optional): ±0.65 %
- Volume flow (steam, gas): ±1.00 %
- Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
- Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
- Mass flow (liquid): ±0.85%
Measuring range
- Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min)
- depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
- Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min)
- depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. process pressure
- PN 100, Class 600, 20K
Medium temperature range
- Standard: –40 to +260 °C (–40 to +500 °F)
- High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
Ambient temperature range
- Compact version (standard): –40 to +80 °C (–40 to +176 °F)
- Compact version (option): –50 to +80 °C (–58 to +176 °F)
- Remote version (standard): –40 to +85 °C (–40 to +185 °F)
- Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing material
- Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing material
- AlSi10Mg, coated; 1.4404 (316L)
Degree of protection
- Compact version: IP66/67, type 4X enclosure
- Sensor remote version: IP66/67, type 4X enclosure
- Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation
- 4‐line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
- Remote display available
Outputs
- 4‐20 mA HART (passive)
- 4‐20 mA (passive)
- Pulse/frequency/switch output (passive)
Inputs
- Current Input 4‐20 mA (passive)
Digital communication
- HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply
- DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
- DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
- DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
- DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvals
- ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
Product safety
- CE, C-TICK, EAC
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates
- ABS, LR, BV, DNV
Pressure approvals and certificates
- PED, CRN, AD 2000
Material certificates
- 3.1 material
- NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)