Specs at a Glance

Wetted materials:
Body: 316L stainless steel

Window: Proprietary material, optimized for bioprocesses

Process connection: PG13.5 for industry standard sensor housings, welded port connectors available

Surface finish: Ra 15 with electropolish

Adhesive: USP Class VI and ISO993 compatible
Sterilization method:
CIP/SIP
Laser wavelength:

785 nm, 1000 nm

Field of application

The Raman Rxn-45 probe capitalizes on the power of Raman in bioprocess manufacturing by measuring multiple, specific components in real-time for continuous, around-the-clock process feedback. It also meets the daunting sampling requirements of compliance, sterilization, port compatibility, and convenience. The Raman Rxn-45 probe was designed for installation in development and cGMP stainless-steel reactors and is successfully used to provide an analytical “eye” into large-scale bioprocesses.

Cell culture: glucose, lactate, amino acids, cell density, titer, and more

Fermentation: glucose, glycerol, acetate, methanol, ethanol, biomass, and more

Key Benefits

  • Measures multiple components in real-time for automated 24/7 process feedback
  • Provides long-term measurement stability
  • Offers a suitable surface finish for cGMP manufacturing
  • Provides compatibility with industry standard bioreactor side ports and sensor housings
  • Offers the flexibility of being installed in development and production reactors
  • Reduces sterilization and cleaning burdens with CIP/SIP standard compatibility

Specifications

Industry

  • Life Science

Product Family

  • Raman

Liquids

Laser wavelength

  • 785 nm, 1000 nm

Spectral coverage

  • Probe spectral coverage is limited by the coverage of the analyzer being used.

Maximum laser power into probehead (mW)

  • < 499

Sample interface

  • Temperature:
  • -30 to 150 °C / -22 to 302 °F
  • Temperature ramp:
  • ≤ 30 °C/min
  • ≤ 54 °F/min

Pressure

  • Max pressure:
  • 13.8 barg / 200 psig

Wetted materials

  • Body: 316L stainless steel
  • Window: Proprietary material, optimized for bioprocesses
  • Process connection: PG13.5 for industry standard sensor housings, welded port connectors available
  • Surface finish: Ra 15 with electropolish
  • Adhesive: USP Class VI and ISO993 compatible

Fiber optic cable

  • Cable sold separately

Length

  • 120 mm / 4.73 inch

Diameter

  • 12 mm / 0.48 inch

Sterilization method

  • CIP/SIP
show more