Promass U 8U5B
Brand: Endress+HauserPromass U 8U5B
Brand: Endress+Hauser
Xpert
Heartbeat Technology Specs at a Glance
Hose connection nipple: Makrolon Rx 1805 polycarbonate
Field of application
Promass U 500 is the ideal single-use flowmeter for biopharmaceutical applications in the life sciences industry. It represents the response to the shift from multi-use to single-use devices and from batch to continuous manufacturing. Offering multivariable measurement, Promass U 500 provides enhanced reliability, high accuracy, and industry compliance according to cGMP. The flowmeter is especially suited for up- and downstream applications in the monoclonal antibodies (mAb) process.
The sensor comprises a disposable part, available in four line sizes, and a permanently installed base unit, fitting all line sizes. Heartbeat Technology automatically recognizes the flow range and verifies the validity of the factory calibration after installation. This simplifies commissioning and eliminates the need for calibration in the field. Equipped with built-in web server, WLAN, and up to 4 I/Os, the transmitter provides easy operation and additional process and device information.
Key Benefits
- Best-in-class measuring accuracy – Coriolis technology with multivariable measurement
- Highest turndown ratio – one sensor fits all line sizes of disposable
- cGMP compliance – designed according to the latest standards and guidelines, equipped with required attributes and documentation
- Simple, fast commissioning – one-hand mounting and automated calibration data transfer
- Self drainability or air bubble escape – thanks to different mounting angles
- No field calibration needed – automated verification with integrated Heartbeat Technology
- Digital integration – modern single pair Ethernet based communication protocols
Specifications
Brand
Industry
- Life Science
Product Family
- Promass
Liquids
Product headline
- Single-use specialist for Biotech applications, with a remote version with up to 4 I/Os.
- Modern fieldbus communication protocols (2-wire).
- Highest measurement performance for liquids in single-use processes for the Life Sciences Industry.
Sensor features
- One sensor fits all DN – single variant with 4 disposable line sizes provides highest turndown ratio . One-hand mounting of disposable – easy
- commissioning due to intuitive clamping mechanism. Mounting angle - self drainabillity or air bubble escape.
- Disposable made of 1.4435 (316L) and polycarbonate. Fully traceable cGMP compliance. One sensor fits four line sizes: ¹⁄₈ to 1".
Transmitter features
- Full access to process and diagnostic information –
- numerous, freely combinable I/Os and Ethernet. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
- Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range
- ¹⁄₈" to 1"
Wetted materials
- Measuring tubes: Stainless steel 1.4435, 316L
- Hose connection nipple: Makrolon Rx 1805 polycarbonate
Measured variables
- Mass, density, temperature
Max. measurement error
- Mass flow (liquid): ±0.5%
Measuring range
- 0 to 75 kg/h (0 to 165,3 lb/min)
Max. process pressure
- 6 bar (87 psi)
Medium temperature range
- 3 to 60°C (37.4 to 140°F)
Ambient temperature range
- 5 to 40°C (41 to 104°F)
Transmitter housing material
- Aluminum, AlSi10Mg, coated
Degree of protection
- Transmitter: IP66/67, Type 4X enclosure
- Sensor: IP54
Display/Operation
- 4-line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
Outputs
- "4 outputs:
- 4-20 mA HART (active/passive)
- 4-20 mA WirelessHART
- 4-20 mA (active/passive)
- Pulse/frequency/switch output (active/passive)
- Double pulse output (active/passive)
- Relay output"
Inputs
- Status input
- 4-20 mA input
Digital communication
- Modbus RS485, PROFINET over Ethernet-APL
Power supply
- AC 100 to 230 V / DC 24 V (non-hazardous area)
Product safety
- CE, C-tick, EAC marking
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Hygienic approvals and certificates
- cGMP compliance, ASME BPE, BPOG, FDA