t-mass 6F5B
Brand: Endress+Hausert-mass 6F5B
Brand: Endress+Hauser
Extended
Heartbeat Technology Specs at a Glance
Max. process pressure:
PN40 / Cl. 300 / 20K
Measuring range:
0.5 to 3750 kg/h (1.1 to 8250 lb/h)
Medium temperature range:
-40 °C to +180°C (-40 °F to +356 °F)
Wetted materials:
Measuring tubes
• DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408
• DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L)
Process connections
Flange connections
Stainless steel, 1.4404 (F316/F316L)
Threaded connections
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
• Stainless steel, 1.4404 (316/316L)
• Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)
• DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408
• DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L)
Process connections
Flange connections
Stainless steel, 1.4404 (F316/F316L)
Threaded connections
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
• Stainless steel, 1.4404 (316/316L)
• Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)
Max. measurement error:
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Field of application
The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter von t-mass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.
Key Benefits
- Measuring principle is characterized by a high operable flow range and direct mass flow measurement
- Measurement of utility and process gases as well as gas mixtures in small line sizes
- Inline version with DN 15 to 100 (1/2 to 4")
- Bidirectional measurement; high measuring performance
- Patented drift-free sensor with SIL 2
- Remote version with up to 4 I/Os
- Backlit display with touch control and WLAN access
- Standard cable between sensor and transmitter
Specifications
Brand
Industry
- Power & Energy
Product Family
- T-mass
Gas
Product headline
- Inline flowmeter with long-term stability as remote version with up to 4 I/Os.
- Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof.
- Measurement of utility and process gases as well as gas mixtures in small line sizes.
Sensor features
- High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Easy maintenance – removable sensor.
- Inline version with DN 15 to 100 (½ to 4"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2.
Transmitter features
- Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
- Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range
- DN 15 to DN 100 (1/2" to 4")
Wetted materials
- Measuring tubes
- • DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408
- • DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L)
- Process connections
- Flange connections
- Stainless steel, 1.4404 (F316/F316L)
- Threaded connections
- Stainless steel, 1.4404 (316/316L)
- Sensing element
- Unidirectional
- • Stainless steel, 1.4404 (316/316L)
- • Alloy C22, 2.4602 (UNS N06022);
- Bidirectional
- Reverse flow detection
Measured variables
- Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density
Max. measurement error
- Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Measuring range
- 0.5 to 3750 kg/h (1.1 to 8250 lb/h)
Max. process pressure
- PN40 / Cl. 300 / 20K
Medium temperature range
- -40 °C to +180°C (-40 °F to +356 °F)
Ambient temperature range
- -40 to 60°C (-40 to 140°F)
- Optional:
- Transmitter: -50 to 60°C (-50 to 140°F),
- Sensor: -60 to 60°C (-60 to 140°F)
Transmitter housing material
- Aluminium, AlSi10Mg, coated
- Polycarbonate
Degree of protection
- IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional)
Display/Operation
- 4-line backlit display with touch control (operation from outside)
- Configuration via local display and operating tools possible
Outputs
- 4 outputs:
- 4-20 mA HART (active/passive)
- 4-20 mA (active/passive)
- Pulse/frequency/switch output (active/passive)
- Relay output
Inputs
- Status input
- 4-20 mA input
Digital communication
- HART, Modbus RS485
Power supply
- DC 24V
- AC 100 to 240V
Hazardous area approvals
- ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC
Product safety
- CE, C-tick
Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
- Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Pressure approvals and certificates
- PED, CRN
Material certificates
- 3.1 material
- NACE MR0175/MR0103